MICCAI 2026 SafeSurg workshop: the 15 accepted papers

Topic notes · MICCAI 2026 (SafeSurg satellite workshop)

Why this page exists

These are the 15 papers accepted at SafeSurg, a MICCAI 2026 satellite workshop on surgical safety, all presented as posters on 26 September 2026. The list and PDFs come from the MICCAI 2026 satellite open-access site. Each paper gets a short note on the task, method, data, key numbers, strengths and limitations. The strengths and limitations are our own reading, not the reviewers’; the OpenReview reviews are linked per paper but not summarised here.

Categorization

Category Papers
Critical View of Safety (lap chole) 011 CasCVS-Net · 020 Frozen FM CVS monitor · 021 PercEVA-CVS · (024 CVMPO in hernia repair)
Trustworthy AI: uncertainty, abstention, auditing, XAI 012 Neighbourhood-Disagreement abstention · 016 XAI for 2D/3D registration QA · 025 Budgeted auditing
Vision-language models 012 Surgical VQA abstention · 023 VLMs rating robotic skill
Skill & adverse-event assessment 023 Skill rating (JIGSAWS) · 027 Bleeding / blood-loss estimation
Scene understanding & detection 001 SG-NCA scene graphs · 024 Gaussian spatial priors (DETR) · 007 Nerve recognition
Segmentation & tracking (video) 008 Stitch-Inferencer · 017 Motion-adaptive temporal smoothing
3D / depth / registration 006 MEDE-TTA depth · 016 Registration quality
Novel sensing 007 Hyperspectral nerve recognition
Efficient / deployable 001 (fanless edge) · 017 (training-free post-filter) · 020 (real-time)
GI / capsule endoscopy 010 Denoising SSL vs foundation models

Main themes: (1) CVS assessment is the most crowded topic, with three papers on Endoscapes / SAGES-2024 where foundation-model backbones now match or beat specialist pipelines. (2) “Safety” increasingly means knowing when the model is wrong: abstention, conformal prediction, audits, failure-mode analysis of VLMs. (3) Deployment constraints in the OR (latency, fanless hardware, no retraining) are treated as first-class goals.

Paper summaries

ID Title Category One-line summary
001 Sterilizable Scene Graph Generation for Operating Rooms Efficient; Scene understanding Neural Cellular Automata scene-graph generator matches SegFormer-based baselines with ~55× fewer parameters, running on fanless phone/Raspberry Pi (1.6–4.5 W); scene-graph evidence relies on pseudo-labels, no on-device FPS.
006 MEDE-TTA: Monocular Endoscopy Depth Estimation via Test-Time Adaptation 3D/depth Augmentation-averaged teacher + stochastic reset + scale-invariant loss on EndoDAC; AbsRel −9% Hamlyn, −7% C3VD, but ~9× slower inference and phantom/limited GT.
007 Hyperspectral Recognition of Pelvic Autonomic Nerves Novel sensing; Detection (colorectal) In-vivo laparoscopic HSI, 13 patients, 3D-CNN: macro-F1 70.5 vs 66.4 for RGB; large inter-patient variance, nerve/fat confusion, non-real-time line-scan camera.
008 Stitch-Inferencer Segmentation & tracking Online instrument-free panorama lets off-the-shelf segmenters/trackers improve without retraining (up to +0.055 Dice); gains uneven (SegFormer worse), planar-homography assumption, 2–4× throughput cost.
010 Self-Supervised Denoising Reconstruction Outperforms Foundation Models for Capsule Endoscopy GI endoscopy Denoising U-Net encoder + fine-tuned EfficientNet-B7: macro-F1 0.842 vs ~0.78 for frozen EndoViT/DINOv2; unfair comparison, missing ablation, title overclaims.
011 CasCVS-Net CVS; Detection Staged detection → segmentation → CVS cascade on Endoscapes: CVS mAP 47.9 → 67.2, rare-anatomy mIoU 4.6 → 15.3; on par with SwinCVS (67.5); baseline numbers copied from papers.
012 Knowing When to Defer: Gradient-Free Abstention for Surgical VQA Trustworthy AI; VLM Votes from Gaussian weight-perturbed copies of a frozen VLM; ECE 0.04–0.07 and better coverage at 70% target accuracy than post-hoc calibration; base accuracy ~0.5, σ tuned per model.
016 Explainable AI for 2D/3D Registration Quality Assessment Trustworthy AI; Registration Fluoro+DRR early-fusion CNN with cross-attention classifies pelvic registration success (mTRE < 2 mm) at 0.801 acc with Grad-CAM + conformal prediction; only 5 specimens, gains within fold variance.
017 Local Motion-Adaptive Temporal Smoothing for Laparoscopic Segmentation Segmentation; Efficient Training-free sparse-optical-flow EMA filter cuts mask flicker at +2.8 ms p90; evaluated on 3 CholecSeg8k videos, no comparison to other temporal methods.
020 What a Frozen Foundation Model Already Knows about CVS CVS; Efficient Frozen SurgeNetXL + LoRA + causal temporal bridge: mAP 0.49, 13.5 ms/frame, NPV ~99% but PPV ≤ 0.19; sparse SAGES-2024 anchors, C1 weak.
021 Annotation-Efficient CVS Assessment with Vision Foundation Models CVS EVA-02-L per-frame + Perceiver temporal head: 69.4 mAP Endoscapes, 65.1 SAGES-2024 without mask/box supervision; temporal head adds only ~2 pp.
023 Can VLMs Safely Rate Robotic Surgical Skill? Skill assessment; VLM Zero-shot GPT/Claude/Gemini on JIGSAWS: best Spearman 0.58, ICC 0.38, scores compressed to mid-scale, kinematics ignored, “respect for tissue” over-scored; expert references fix calibration not ranking.
024 Gaussian Spatial Priors for Anatomy-Aware Detection Detection; CVMPO (hernia) Parameter-free Gaussian prior in DAB-DETR self-attention: epigastric-vessel AP50 0.212 → 0.283; small private set (619 frames / 119 videos).
025 Auditing Surgical-AI Models Under an Annotation Budget Trustworthy AI (auditing) Fixed-budget audit protocol (uniform cohort, confidence-blind probe, BH-corrected confirmation) gives unbiased error estimates (coverage 0.96–0.99); confident-wrong errors are 12–20% of errors; single-site simulation.
027 Hemorrhage First: Video-based Blood Loss Estimation Event assessment (bleeding) New 66-video robotic liver-resection dataset; ordinal+prototype MViT for clip-level bleeding severity (acc 0.633, macro-F1 0.464) and surgery-level loss category (56.1%); very small test sets.

Recurring weaknesses (our own critical read)

Paper notes

001 · Sterilizable Scene Graph Generation for Operating Rooms

page · PDF · OpenReview

Authors (first/last): Nick Lemke / Anirban Mukhopadhyay · Affiliation: TU Darmstadt (with ImFusion, Carl Zeiss AG, UMM Mainz, Inria)

Task / clinical problem: Surgical scene graph generation (tools, anatomy, relations) normally needs heavy GPU workstations that are hard to sterilize, fan-cooled and bulky; the goal is OR-ready inference on fanless edge devices.

Category tags: Efficient / deployable models; Scene understanding & detection. Domain: cataract surgery and laparoscopic cholecystectomy.

Method: SG-NCA uses an OctreeNCA (Neural Cellular Automata) for multi-class segmentation. Masks give graph nodes (>150 px), segmentation-grounded pooled features (64-d, fused over 7 frames to 256-d) go to a small relation predictor over all object pairs. A class-incremental curriculum trains 5 frequent classes first, then adds hidden channels while freezing old parameters, making many-class NCA training feasible. Rule-based captions are generated from the graphs.

Data & evaluation: Cholec80 / CholecSeg8k / CholecT50 and CATARACTS / CaDIS / CAT-SG; mostly SASVi (SAM2) pseudo-masks for training, GT masks for val/test; patient-level splits. Dice for segmentation; unconstrained Recall@K, mRecall@K, mAP@K for relations. Baselines: UNet, tinyUNet, SegFormer, SwinUNetV2 + MotifNet. Device benchmark: workstation, smartphone, Raspberry Pi.

Key results: Macro Dice 70.9 (chole) / 75.0 (cataract) with 27k / 42k params vs SegFormer 71.3 / 70.8 with 3.7M. About 55x fewer parameters than the lightest baseline for similar SGG performance. Smartphone: +0.66 K, 1.6 W; Pi: +0.62 K, 4.5 W; workstation: +4.18 K, 223 W.

Strengths: - Concrete, hygiene-motivated deployment argument backed by thermal/power measurements. - Curriculum for NCAs is a simple, reusable idea; ablation shows robustness to size. - Code released.

Limitations / open questions: - SGG results are only in a figure, with pseudo-label supervision; no latency/FPS on the edge devices and no accuracy-on-device check. - Small data (“two video recordings” claimed), no confidence intervals or significance; “comparable” is judged loosely, and SegFormer baseline wins on chole Dice. - Captions are rule-based and unevaluated; no clinical or safety-relevant downstream validation; other SGG methods (e.g., ORacle, S2Former-OR) not compared.

006 · MEDE-TTA: Cross-Scenario Monocular Endoscopy Depth Estimation via Test Time Adaptation

page · PDF · OpenReview

Authors (first/last): Liangjing Shao / Hongliang Ren · Affiliation: CUHK (Dept. of Electronic Engineering) and Shenzhen Loop Area Institute; Univ. of Manchester

Task / clinical problem: Monocular endoscopic depth models trained in one setting fail on other hospitals, scopes and anatomy; adapt online without labels for safer 3D perception.

Category tags: 3D / depth / registration; Efficient / deployable models. Domain: laparoscopy and colonoscopy.

Method: Continual test-time adaptation on top of EndoDAC (ViT + DV-LoRA + DPT head; only LoRA and head updated). Aug-Teacher averages EMA-teacher predictions over K color-jittered views, gated by anchor-model confidence (falls back to plain EMA teacher). Stoch-Reset randomly restores each adapted parameter to the source snapshot (p=0.01) after each step to prevent drift. A scale-invariant log-depth consistency loss, grouped learning rates and dual-rate EMA complete it.

Data & evaluation: Zero-shot SCARED -> Hamlyn (91,866 frames) and SimCol (simulated) -> C3VD (colon phantom, 3,166 frames). AbsRel, SqRel, RMSE, RMSE-log, delta<1.25. Baselines: EndoDAC, IID-SfMLearner, MonoPCC, DA v2, and TTA methods CoMoDA, CoTTA, AdaDepth, TEA, REM. Single RTX 4090.

Key results: Hamlyn AbsRel 0.142 vs EndoDAC 0.156 (-9.0%), RMSE 11.79 vs 12.94, delta 0.806 vs 0.791. C3VD AbsRel 0.118 vs 0.127, delta 0.873 vs 0.853; RMSE gain only 0.96%. Ablations show each component helps. Cost is 106 ms/frame on C3VD (vs 11.7 for the baseline), 1.9 GB memory.

Strengths: - Label-free, practical framing with comparison to many TTA baselines under the same backbone. - Simple, low-parameter mechanisms; ablation on both datasets. - Code released.

Limitations / open questions: - Gains are modest and the other TTA methods often degrade the baseline, so the margin over source model matters; no variance across seeds or stream orders. - Hamlyn lacks true GT depth in most frames and C3VD is a phantom, so clinical validity (in vivo accuracy) is untested. - About 9x slower than the baseline, well short of real-time; hyperparameters (K, thresholds) differ per dataset and are not tuned/justified under a true no-label protocol.

007 · Hyperspectral Recognition of Pelvic Autonomic Nerves for Safety-Aware Colorectal Surgery

page · PDF · OpenReview

Authors (first/last): Farid Harb / Dirk Wilhelm · Affiliation: Technical University of Munich (TUM School of Medicine and Health, MITI group; Dept. of Surgery, TUM University Hospital)

Task / clinical problem: Autonomic nerve injury in colorectal surgery causes urinary, bowel and sexual dysfunction; nerves are hard to see. Can intraoperative hyperspectral imaging (HSI) identify them?

Category tags: Novel sensing (hyperspectral etc.); Scene understanding & detection. Domain: colorectal surgery (robotic/laparoscopic).

Method: Line-scanning laparoscopic HSI (100 bands, 500-995 nm, 720x540 cube). After preprocessing (spatial smoothing, SNV normalization) and class-balanced sampling, pixel-wise classification of nerve / fat / blood vessel / instrument with SAM (spectral angle), SVM, random forest, XGBoost, MLP and a 3D-CNN on center-pixel patches. Also compares HSI vs RGB vs handcrafted indices (NIRPI, OHI, StO2, TLI, TWI) and permutation wavelength importance.

Data & evaluation: 13 patients, 124 annotated acquisitions (expert CVAT labels on reconstructed RGB; 80 acquisitions contain nerve, ~564k nerve pixels). Leave-one-patient-out CV; macro precision/recall/F1 plus nerve precision/recall.

Key results: 3D-CNN best: macro F1 70.47 +/- 11.69; nerve P 69.21 +/- 25.68, R 70.70 +/- 15.55. Same 3D-CNN: RGB macro F1 66.44, indices 64.80. Wavelengths below 600 nm most important. Nerve mostly confused with fat (19%); inference 0.44 ms/patch.

Strengths: - Rare in-vivo human HSI dataset with patient-level cross-validation. - Direct HSI vs RGB comparison and interpretable spectral analysis. - Targets a clearly safety-relevant structure.

Limitations / open questions: - Small cohort and huge fold variance (nerve precision SD 25.7); HSI vs RGB gain (~4 F1 points) is not tested for significance. - Annotation on RGB reconstructions without histology confirmation; pixel-level only, no spatial/segmentation-level or per-acquisition clinical metrics; other classes annotated opportunistically. - Line-scan acquisition is not real-time, so intraoperative use is unproven; false-positive vessels would matter for safety.

008 · Stitch-Inferencer: Enhance Endoscopic Video Segmentation and Tracking via Panoramic Reconstruction

page · PDF · OpenReview

Authors (first/last): Shunsuke Kikuchi / Hiroki Matsuzaki · Affiliation: Jmees Inc., Chiba, Japan

Task / clinical problem: Narrow field of view and tool occlusions make per-frame anatomy segmentation and tracking brittle; want long-range context without training heavy video models.

Category tags: Segmentation & tracking; Efficient / deployable models. Domain: laparoscopic cholecystectomy (plus STIR and SurgT tracking data).

Method: An online, model-agnostic wrapper builds an instrument-free panoramic canvas: invalid regions (border, tools, trocar ports via ConvNeXt U-Nets) are masked, ALIKED+LightGlue keypoints give a weighted-DLT homography, a cumulative warp composites sharp frames (blur gating, seam-aware alpha blending) with re-anchoring on extreme motion. Any segmentation/tracking model runs on a compact ROI of the panorama and the output is reprojected to the current frame, with no retraining.

Data & evaluation: CholecSeg8k (5-fold CV, macro Dice and peripheral Dice) with five single-frame baselines plus temporal/SAM3 video baselines; STIR24 (point tracking, delta-avg, mean distance) and SurgT (EAO, 2D/3D error) with CSRT, CoTracker3, LiteTracker, MFT. FPS and p95 latency.

Key results: UNet++ Dice 0.688 -> 0.744 (+0.055); UPerNet +0.010, DeepLabV3+ +0.023, HRNet +0.007, SegFormer -0.013. Segmentation drops to ~45-52 FPS from 100-212. Tracking improved for CSRT, CoTracker3 (EAO 0.453 -> 0.602), small or mixed gains for LiteTracker/MFT (LiteTracker delta-avg unchanged, Err3D slightly worse). Stitching alone 63 FPS; canvas reset in 0.09% of frames.

Strengths: - Interpretable explicit spatial memory; no retraining needed; works across many models. - Honest reporting incl. the SegFormer regression and latency cost. - Broad evaluation on segmentation and two tracking benchmarks, code released.

Limitations / open questions: - Planar homography fails under deformation/parallax and there is no canvas correction; gains concentrated on one baseline and mostly small elsewhere, without significance testing. - Tool/port masks and stitching are trained on other datasets (Dice 0.86/0.77); CholecSeg8k is short clips, so long-horizon benefit is untested. - No clinical/safety endpoint (e.g., CVS, error reduction); authors are company employees.

010 · Self-Supervised Denoising Reconstruction Outperforms Foundation Models for Capsule Endoscopy Abnormality Classification

page · PDF · OpenReview

Authors (first/last): Vamshi Krishna Kancharla / Kaveti Pavan Kumar · Affiliation: Indian Institute of Science, Bangalore; independent researcher (India); Hokkaido University

Task / clinical problem: Reviewing hundreds of thousands of capsule endoscopy frames is slow; classify ten GI abnormality classes under severe class imbalance.

Category tags: Endoscopy (GI/capsule); Efficient / deployable models (weak). Domain: video capsule endoscopy.

Method: A U-Net autoencoder is pretrained self-supervised on VCE images to reconstruct clean images from Gaussian-noised (or patch-masked) inputs; noise worked better than masking. Its pooled encoder features are concatenated with fine-tuned ImageNet EfficientNet-B7 features and fed to a fully connected softmax classifier (Adam, lr 1e-4, batch 256).

Data & evaluation: Capsule Vision 2024 Challenge: 37,607 train, 16,132 validation frames, 10 classes (Normal 12,287 in val; Worms 68), official splits. Macro-F1 and balanced accuracy; baselines are frozen EndoViT and DINOv2 + MLP (with augmentation/DDPM variants).

Key results: Macro-F1 0.842, accuracy 0.940, weighted F1 0.939. Baselines: EndoViT 0.777, DINOv2 0.787-0.795 macro-F1. Per-class F1: ulcer 0.982, normal 0.982, worms 0.971, bleeding 0.831; weak on erythema 0.572, polyp 0.721.

Strengths: - Clear, reproducible setup on a public challenge benchmark with per-class reporting. - Honest about weak minority classes and lack of temporal modeling. - Simple, annotation-free pretext task.

Limitations / open questions: - Unfair comparison: frozen ViT + MLP versus a fully fine-tuned EfficientNet-B7; no fine-tuned CNN-only baseline or ablation isolating the U-Net branch’s contribution is given, so the title’s SSL claim is unsupported. - “Balanced accuracy 0.940” equals overall accuracy in Table 3 (macro recall is 0.835), so that metric appears misreported; evaluation is on validation set only (no test set, one run, no CIs, possible patient leakage unaddressed). - Frame-level, no temporal or lesion-level analysis; B7 is heavy for deployment; “outperforms foundation models” is overclaimed.

011 · CasCVS-Net: A Staged Multi-Task Cascade for Critical View of Safety Assessment

page · PDF · OpenReview

Authors (first/last): Bock-Zien Toh, Yuanchuan Ren (equal) … Zhehua Mao, Sophia Bano · Affiliation: Dept. of Computer Science / UCL Hawkes Institute, University College London, UK

Task / clinical problem: Automated CVS assessment in laparoscopic cholecystectomy to prevent bile duct injury; the bottleneck is grounding small, rare, occluded hepatocystic anatomy (cystic plate, hepatocystic triangle).

Category tags: Critical View of Safety; Scene understanding & detection. Domain: lap chole.

Method: A shared ResNet-50-FPN with task-specific residual adapters feeds three heads: Faster R-CNN detection, DeepLabV3+ segmentation, and a CVS classifier. Predicted boxes are rasterised into a confidence-weighted spatial prior added residually to the segmentation decoder (box-to-mask). Predicted masks pool class-wise features for the CVS head (mask-to-CVS). Training is staged (detection, then det+seg, then full cascade with PCGrad, then per-head fine-tuning); no GT boxes/masks are needed at inference.

Data & evaluation: Endoscapes2023 (201 videos; 120/41/40 official split; CVS labels on 11,090 frames, boxes on 1,933, masks on Seg50 subset). Metrics: box mAP, semantic mIoU (plus rare-class cystic plate/triangle), CVS mAP and balanced accuracy. Baselines: framework-matched single-task models; CVS numbers for LG-CVS, SV2LSTG, SwinCVS-Frozen copied from their papers.

Key results: vs. single-task: det mAP 29.6 to 32.0, rare mIoU 4.6 to 15.3, mIoU 38.4 to 46.8, CVS mAP 47.9 to 67.2. CVS mAP 67.2 / bAcc 74.7 vs SwinCVS 67.5 / 70.3, LG-CVS 63.2 / 74.8. Joint single-stage training fails (det 3.9 mAP, CVS 28.0). Removing mask-to-CVS drops CVS to 55.8; removing box-to-mask drops it to 62.1.

Strengths: - Clean ablations showing staging is essential and mask-to-CVS drives CVS gains. - Reports rare safety-critical classes separately, not just averages. - Train/test consistent (predicted, not GT, boxes/masks).

Limitations / open questions: - Literature CVS comparisons use copied numbers (likely different backbones/data use); single run, no seeds or confidence intervals, and gains over published methods are mixed (mAP slightly below SwinCVS). - Segmentation only on small Seg50 subset; segmentation not comparable to published instance-AP; no runtime/memory despite multi-head cascade. - No analysis of error propagation or failure cases; no clinical/prospective validation or calibration of CVS outputs.

012 · Knowing When to Defer: Gradient-Free Abstention for Vision-Language Models in Surgical VQA via Neighbourhood Disagreement

page · PDF · OpenReview

Authors (first/last): Pramit Saha … Mitchell A. Stotland · Affiliation: Dept. of Engineering Science, University of Oxford, UK; Dept. of Surgery, Sidra Medicine / Weill Cornell Medicine, Qatar

Task / clinical problem: Frozen VLMs answer surgical VQA confidently even when wrong; need a way to abstain/defer to the surgeon without fine-tuning or logit access.

Category tags: Trustworthy AI (uncertainty, abstention); Vision-language models. Domain: lap chole (Cholec80-VQA), endoscopic submucosal dissection (CoPESD), SSG-VQA scene graphs.

Method: “Neighbourhood Disagreement” samples M=30 perturbed copies of a frozen VLM by adding Gaussian noise N(0, sigma^2) to weights (“neural thicket”). Each perturbed expert votes on the multiple-choice answer; Dirichlet-smoothed vote concentration gives confidence, and 1 - max vote share is the epistemic uncertainty used for abstention. The radius sigma acts as a weight-space temperature: too small keeps overconfidence, too large causes an accuracy cliff; the useful regime is near the “edge of competence” (sigma ~0.004 for Qwen2.5-VL-7B).

Data & evaluation: Three surgical VQA sets (CoPESD, Cholec80-VQA, SSG-VQA), four VLMs, per-category breakdowns. Metrics: ECE, confidence-accuracy gap, AURC, coverage at target selective accuracy. Baselines: MaxP, temperature, Platt, isotonic, histogram binning. Ablation over M.

Key results: At sigma=0.004, ECE 0.25/0.22/0.23 to 0.04/0.07/0.04 (CoPESD/Cholec80/SSG; abstract cites 0.27/0.28/0.30 baselines); AURC 0.42 to 0.35 (CoPESD), 0.44 to 0.37 (SSG). Coverage at 70% target accuracy: 33/30/22% vs <=10% for best baseline. Accuracy stays ~0.50-0.55 at M=30.

Strengths: - Practical: forward passes only, no labels, logits, or gradients. - Shows post-hoc calibration cannot fix ranking for abstention, with coverage-at-target-accuracy a deployment-relevant metric. - Honest about the accuracy cliff and sensitivity to M.

Limitations / open questions: - Absolute accuracy is low (~0.5), so even 70% selective accuracy covers only 22-33%; clinical usefulness unclear. - sigma* is tuned per model/dataset (and appears picked using the same evaluation data despite “no labelled validation” claim); transferability across models is only qualitatively shown. - Cost is M=30 forward passes per query; no comparison to sampling-based/verbalised-confidence or ensemble baselines, and logit-free baselines like MaxP/temperature are weak straw men.

016 · Explainable AI for Image-based 2D/3D Registration Quality Assessment

page · PDF · OpenReview

Authors (first/last): Sue Min Cho … Mathias Unberath · Affiliation: Johns Hopkins University, Baltimore, USA

Task / clinical problem: Automatically judge whether a fluoroscopy-to-CT 2D/3D registration is successful (mTRE < 2 mm) so misalignments are caught in image-guided orthopedic surgery.

Category tags: Trustworthy AI (uncertainty, XAI); 3D / depth / registration. Domain: orthopedic pelvic fluoroscopy.

Method: Early fusion (channel concatenation) of the X-ray and the DRR rendered at the estimated pose, passed through a 5-block CNN. Features are split channel-wise into two token groups with bidirectional spatial cross-attention, then a linear classifier predicts accept/reject. Grad-CAM gives spatial attribution and split conformal prediction (alpha=0.1, calibrated on validation set) flags uncertain cases (two-label sets).

Data & evaluation: Public pelvic cadaver dataset, 5 specimens; DeepDRR adds simulated projections (200 per specimen); 100 registrations per projection from a single-view registration method gives ~100,000 DRRs. Leave-one-specimen-out CV, tested on real projections only. 2x2 ablation (cross-attention x simulated data); accuracy, sensitivity, precision, specificity.

Key results: Proposed + real+sim: accuracy 0.801 +/- 0.030, precision 0.688, specificity 0.806, sensitivity 0.766. Baseline real+sim: 0.777 +/- 0.135 (sens 0.880, spec 0.747). Cross-attention alone gives 0.772 vs 0.758 on real data.

Strengths: - Frames QA of registration as an explicit safety layer with human-in-the-loop outputs (heatmap + certainty). - Specimen-level LOOCV and reporting of variance, rather than random frame splits. - Code released; clear 2x2 ablation.

Limitations / open questions: - Gains are small relative to fold SD (e.g. 0.801 vs 0.777 with baseline SD 0.135) on only 5 specimens, no significance testing; ~80% accuracy is modest for a safety gate and sensitivity actually drops. - Conformal coverage, set-size distribution, and Grad-CAM faithfulness are never quantified; XAI is shown by four anecdotal cases and no user study. The “clinically preferable” conservative-boundary claim rests on specificity differences within noise. - Single anatomy, one registration algorithm, fixed 2 mm threshold; synthetic failures from random initialisation may not match real failure modes.

017 · Local Motion-Adaptive Temporal Smoothing for Real-Time Laparoscopic Video Segmentation

page · PDF · OpenReview

Authors (first/last): Minato Yamashita … Masaaki Ito · Affiliation: Dept. for the Promotion of Medical Device Innovation & Dept. of Colorectal Surgery, National Cancer Center Hospital East, Japan

Task / clinical problem: Frame-wise segmentation masks flicker; fixed-coefficient EMA smoothing trades stability against lag in moving regions. Goal: stable yet responsive real-time masks for intraoperative support.

Category tags: Segmentation & tracking; Efficient / deployable models. Domain: lap chole (CholecSeg8k); authors from colorectal surgery.

Method: Training-free, model-agnostic post-processing on class probability maps. Sparse Lucas-Kanade flow on a grid gives per-block motion (90th-percentile magnitude on 6x6 blocks), mapped through a smoothstep (tau_low, tau_high) to an EMA coefficient between 0.1 and 0.9, bilinearly upsampled to a pixel-wise map. Static regions are smoothed strongly, moving regions follow the current frame; causal, no future frames.

Data & evaluation: CholecSeg8k (8,080 frames, 17 videos), 4 foreground classes (liver, fat, abdominal wall, gallbladder), 3 held-out test videos. Base model FPN + EfficientNetV2-S (512x288), TensorRT FP16 on a laptop RTX 3080 Ti. Metrics: inter-frame Boundary IoU (stability) and frame-wise Boundary IoU vs GT (responsiveness), stratified by Farneback-derived motion bins; baselines no filter and fixed EMA (alpha 0.1-0.9).

Key results: Low-motion stability close to EMA alpha=0.1 while high-motion Boundary IoU approaches the no-filter level, whereas small-alpha EMA degrades. Sparse-flow motion correlates with Farneback (Spearman 0.78). p90 latency 9.41 ms vs 6.63 ms (no filter), +2.78 ms, versus 33 ms frame budget.

Strengths: - Simple, plug-in, deployable; latency measured end to end on realistic hardware. - Motion-stratified evaluation directly exposes the stability/responsiveness trade-off. - Limitations section is candid.

Limitations / open questions: - Evidence is mainly curves on 3 videos with 4 classes and no headline numbers or statistics; no comparison to ViperSAM/MCMA or learned temporal models, which motivate the work. - Inter-frame Boundary IoU penalises true motion; CholecSeg8k is sparse short clips at 25 fps, so long-run behaviour (smoke, camera motion, global motion) is untested; thresholds are hand-set in pixels and resolution-dependent. - No clinical outcome (e.g. whether less flicker aids surgeons) and no evaluation of Go/No-Go zones named in the motivation.

020 · What a Frozen Foundation Model Already Knows about the Critical View of Safety: Toward a Real-Time Monitor

page · PDF · OpenReview

Authors (first/last): Soham Chaudhuri … Ana Manzano Rodriguez · Affiliation: University of Amsterdam (HAVA-Lab, VISlab); Amsterdam UMC Surgery; Amsterdam Public Health

Task / clinical problem: Continuous, real-time CVS verification to prevent bile duct injury, under scarce labels and latency constraints.

Category tags: Critical View of Safety; Efficient / deployable models (also Trustworthy AI). Domain: lap chole.

Method: Benchmarks five frozen backbones (EVA-02, C-RADIO-v4, SurgeNetXL, SurgCLIP, UniSurg), picks SurgeNetXL (DINOv3 ViT-L), and tests five questions: explicit depth/SAM2 fusion, CKA and null-space concept erasure of depth, adaptation level (frozen/last-block FT/LoRA), sparse causal temporal attention, and a confidence-decaying causal label propagation from 18 anchors per video. The deployed “causal bridge” is a small causal transformer over a ring buffer of frozen features.

Data & evaluation: SAGES 2024 CVS Challenge: 1,000 videos (700/300), 54 institutions, 18 labelled anchor frames each (1 per 5 s, 90 s before first clip), ~2% positive frames. mAP primary; backbone selection by 5-fold linear probe, rest on the official split; bridge over 3 seeds.

Key results: SurgeNetXL linear probe mAP 0.534 vs 0.283 (C-RADIO-v4). Depth+SAM2 add only +1.2 pp; RGB-depth CKA 0.76; depth erasure: C3 -0.0137, C1 +0.0129. LoRA 0.48 vs full FT 0.43 vs frozen 0.41. Best temporal window 2-3 frames (mAP 0.576). Causal bridge 0.49 +/- 0.06 (13.5 ms/frame, AUROC 0.85, NPV ~0.99, PPV <= 0.19); fancier models reach only 0.46.

Strengths: - Asks “what does the frozen model already know” with a systematic RQ structure and honest negative results. - Safety-aware framing: rule-out monitor, high-NPV operating point, PPV limits at 2% prevalence. - Real-time, causal, latency independent of clip length.

Limitations / open questions: - Evaluation is only on sparse anchor frames, retrospectively; the dense causal bridge was never evaluated on true frame-level labels, so online behaviour is inferred. - Many results are single runs with small differences (0.0022, 0.0129 deltas) and different protocols; “suggestive” depth-use claim is weak, and the “label ceiling” explanation is untested. - mAP ~0.49 and weak C1 (the injury-relevant criterion) fall far short of clinical use; no external dataset or comparison to published CVS methods.

021 · Annotation-Efficient Critical View of Safety Assessment with Vision Foundation Models

page · PDF · OpenReview

Authors (first/last): Sergio Cañar / Pablo Arbeláez · Affiliation: Universidad de los Andes, Bogotá, Colombia

Task / clinical problem: Automatically decide whether each of the three CVS criteria (C1 two structures, C2 cleared hepatocystic triangle, C3 cystic plate) is met in lap chole video, to help prevent bile duct injury, without needing masks, boxes or text prompts.

Category tags: Critical View of Safety; Efficient / deployable models. Domain: laparoscopic cholecystectomy.

Method: Stage 1 fine-tunes a general-domain EVA-02 L encoder per frame (weighted BCE, 448x448, 1 fps), chosen after benchmarking five encoders (CLIP, Swin-L, DINOv2, DINOv3, EVA-02). Stage 2 freezes it and trains PercEVA-CVS: a keyframe-anchored Perceiver (K=64 latents seeded with the current frame, N=2 gated-residual blocks) that cross-attends over a 15 s causal window of embeddings and reads out the keyframe token. An end-to-end variant unfreezes the last four encoder blocks.

Data & evaluation: Endoscapes 2023 (201 videos, 11,090 frames, official splits) and SAGES 2024 (1,000 90 s clips, 700/300 split, no masks or boxes). Metric: mAP over the three criteria, mean ± std over 3 seeds, paired t-tests. Baselines re-trained: LG-CVS, SV2LSTG, CVS-AdaptNet, SwinCVS.

Key results: Encoder benchmark: EVA-02 L 67.68 mAP (Endoscapes) and 63.32 (SAGES), vs DINOv3 62.30 and 60.90. Per-frame EVA-02 alone beats prior work (Endoscapes 67.7 vs best baseline SV2LSTG-box 65.8). PercEVA-CVS 69.4 (Endoscapes) and 65.1 (SAGES); E2E 70.5 and 64.7. On SAGES it beats SwinCVS Frozen by 13.5 pp. Latency 37.5 ms/keyframe frozen, ~400 ms E2E. Ablations: window length and Perceiver vs LSTM not significantly different.

Strengths: - Clean controlled encoder comparison and re-training of baselines on a new benchmark (SAGES), with seeds and significance tests. - Shows supervision-free FM fine-tuning is competitive, which lowers annotation cost. - Honest ablations: temporal module gain is small and the paper says so.

Limitations / open questions: - Gains over the per-frame FM are modest (+1.7 and +1.8 pp) and not significant on SAGES (p=0.09); only 3 seeds, so t-tests are weak. - 304M-parameter encoder; frozen pipeline reads stored embeddings, so real intraoperative suitability is unproven. No calibration, uncertainty or external-site evaluation. - Absolute mAP (~65-70) is still low for a safety-critical decision; C2 remains weak, and label noise from poor annotator agreement is not analysed.

023 · Can Vision-Language Models Safely Rate Robotic Surgical Skill? A Failure Mode Analysis with Video, Kinematics, and Expert References

page · PDF · OpenReview

Authors (first/last): Siying Chen / Xianyi Cheng · Affiliation: Duke University, Durham, NC, USA

Task / clinical problem: Test whether frontier VLMs can act as zero-shot raters of robotic surgical skill (modified OSATS GRS), and whether their errors come from missing evidence or from failing to use it.

Category tags: Skill & event assessment; Vision-language models (also Trustworthy AI via failure-mode analysis). Domain: robotic dry-lab training (da Vinci, JIGSAWS).

Method: Zero-shot prompting of GPT-5.5, Claude Opus 4.8 and Gemini 3.5 Flash to score six GRS components (1-5, sum 6-30) under controlled evidence: video frames only (1/2/3 fps), a text kinematic summary only, both (“kinematic grounding”), interpreted grounding, and retrieved expert-scored reference examples. A ridge regressor on the same nine kinematic features serves as an information-matched floor.

Data & evaluation: JIGSAWS, 102 trials (Suturing 38, Knot Tying 36, Needle Passing 28). Metrics: Spearman rho and ICC(2,1) against expert total GRS, bootstrap CIs (2,000 resamples) and paired bootstrap differences.

Key results: Best vision-only: GPT-5.5 at 3 fps, rho 0.58, ICC 0.38; Claude 0.23-0.32 rho; Gemini near zero. Predictions compress to mid-scale (strong under-scored, weak over-scored). Kinematics-only VLMs ICC ≤ 0.06 vs ridge 0.44 (rho 0.45). Adding kinematics to video lowers GPT-5.5 (rho 0.58 to 0.39). Expert references raise ICC 0.24 to 0.43 but rho stays ~0.49. Component bias: respect for tissue +1.02 (over-scored), flow of operation -0.42, final product -0.43.

Strengths: - Diagnostic design (evidence ablations plus a trivial regressor floor) isolates why VLMs fail rather than just reporting a score. - Separating rank agreement (rho) from absolute agreement (ICC) exposes range compression. - Component-level bias analysis ties failure to safety-relevant, video-unobservable dimensions.

Limitations / open questions: - Only 102 JIGSAWS dry-lab trials, a few novice-heavy surgeons; no clinical or live-surgery data, so “safe skill rating” claims do not generalise. - Proprietary, snapshot models and a single prompt family; the kinematic text summary may be a poor VLM input, so the “cannot use kinematics” conclusion is prompt-dependent. No open-weight or fine-tuned VLM or supervised video baselines. - Ridge is evaluated with leave-one-surgeon-out while VLM conditions are zero-shot, and expert-reference examples drawn from the same pool risk leakage; reference-selection details matter.

024 · Gaussian Spatial Priors for Anatomy-Aware Object Detection in Surgical Videos

page · PDF · OpenReview

Authors (first/last): Yunfan Li / Himanshu Gupta · Affiliation: Stony Brook University and Stony Brook University Hospital, NY, USA

Task / clinical problem: Detect anatomical landmarks for the Critical View of the Myopectineal Orifice (CVMPO) in inguinal hernia repair, especially small, intermittently visible structures such as epigastric vessels.

Category tags: Scene understanding & detection; Critical View of Safety (CVMPO analogue). Domain: laparoscopic/robotic TAPP inguinal hernia repair.

Method: A Gaussian Spatial Prior (GSP) is added to DAB-DETR. Cooper’s ligament (CL) and Triangle of Doom (DOOM) are “anchor” classes; epigastric vessels (EPI) are “dependent”. Per anchor-dependent pair, 2D Gaussians over anchor-size-normalised centre offsets are fitted offline from training boxes and frozen. At each decoder layer, pairwise query compatibility (max over Gaussians) is zero-centred, scaled by lambda and added to self-attention logits, recomputed as reference boxes refine. No learned parameters.

Data & evaluation: Proprietary set of 619 frames from 119 videos (3 classes, ~1,142 boxes), video-level 5-fold CV. COCO AP/AP50; baselines YOLOv26, DETR, DAB-DETR (ResNet-50, COCO-pretrained); lambda ablation {1,3,5,7}; paired one-sided t-test.

Key results: GSP (lambda=3) mAP50 0.648 vs DAB-DETR 0.593, DETR 0.615, YOLOv26 0.592; mAP 0.256 (YOLOv26 best at 0.262). EPI AP50 0.283 vs 0.212 DAB-DETR (+33.5%) and 0.184 YOLOv26 (+53.9%); anchor AP50 0.831 vs 0.784 (+6.0%). p = 0.012. Performance peaks at lambda=3 and drops at 5 (EPI AP50 0.180).

Strengths: - Simple, interpretable, parameter-free way to inject anatomical knowledge; sensible for data-scarce rare procedures. - Video-level CV avoids patient leakage; per-class reporting shows where the gain comes from. - Targets a CVS-like safety framework that is under-studied in computer vision.

Limitations / open questions: - Small, private, hand-selected frames (mean 5 per video, only pre-mesh stages), so no consecutive-video or deployment-like evaluation; results not reproducible. Intro says robotic TAPP while methods say laparoscopic. - Headline relative percentages rest on low absolute numbers (EPI AP 0.078, AP50 0.283); standard deviations are large (EPI ±0.07), and the improvement over plain DETR is small (+3 pp mAP50). Lambda selected on the same folds used for reporting. - Only 3 classes and one anchor-dependent structure; no test of robustness when anchors are missed or anatomy is distorted; the link from detection to actual CVMPO assessment is not shown.

025 · Auditing Surgical-AI Models Under a Fixed Annotation Budget: Unbiased Performance and Confirmed Failure Modes

page · PDF · OpenReview

Authors (first/last): Yann Sakref / Lisa M. Knowlton · Affiliation: Stanford University (Dept. of Surgery); Johns Hopkins University (Dept. of Surgery)

Task / clinical problem: Help a deployment site audit a frozen surgical AI model with limited expert labels: obtain an unbiased error rate and locate where the model fails, including confident-wrong (“silent”) failures.

Category tags: Trustworthy AI (uncertainty, auditing, XAI). Domain: lap chole phase recognition and segmentation, pituitary surgery VQA.

Method: A fixed label budget is split: 40% for a uniform-random cohort (Track A) giving an unbiased headline error with Wilson/bootstrap interval; a confidence-blind linear probe on embeddings is trained on Track A to score the pool, and high-scoring inputs are clustered (GMM-BIC) into candidate regions; 60% buys fresh disjoint labels (Track B, 25 per region) to test each region one-sided against the baseline with Benjamini-Hochberg correction. Confirmed regions are tagged silent or loud by model confidence.

Data & evaluation: Simulated audits (300 repeats, budget 20% of the pool) on five model-dataset pairs: three Cholec80 phase models (acc. 0.55/0.61/0.79), PitVQA-Net on PitVQA (0.73), FCN-ResNet50 on CholecSeg8k (mIoU 0.68). Compared with confidence-sampled naive IPW and active prediction-powered inference. Pools are small (~230-1,200).

Key results: Uniform headline: SE 3-5 pp, coverage 0.96-0.99, worst single audit ≤ 9 pp; IPW/active PPI coverage falls to 0.68-0.70 with worst errors 37-65 pp on overconfident models. Confident-wrong errors are 12-20% of errors and do not shrink with better models; probe AUC 0.66-0.75 among confident frames. Reusing discovery labels confirms spurious regions in 0.81-1.00 of null audits; Track B + BH gives 0.05-0.14 (target 0.05). Confirmed regions: adjacent-phase confusions, VQA question types, gallbladder/hepatocystic-triangle segmentation.

Strengths: - Rigorous statistical framing: unbiased headline, disjoint-label confirmation and multiplicity control address circular failure discovery. - Shows concretely that confidence-based sampling and flagging miss silent failures. - Practical output (headline, failure map, reusable labeled cohort) for post-deployment surveillance.

Limitations / open questions: - Only simulation on single-site public data; no real distribution shift, no real annotators or label noise, so the deployment claim is a proof of concept. - False-confirmation rate exceeds the nominal 5% on VQA (0.10) and segmentation (0.14); segmentation affords only one region. Budget (20%) and 40/60 split are fixed, not tuned or sensitivity-tested. - Uniform-sample baseline is only compared with confidence-driven ones, not with uniform+PPI or slice-discovery methods; the silent-failure probe is weak (AUC ≤ 0.77) and recovers up to 25% of silent failures.

027 · Hemorrhage First: Rethinking Surgical Safety Assessment via Video-based Blood Loss Estimation

page · PDF · OpenReview

Authors (first/last): Pengfei Li / Joël L. Lavanchy · Affiliation: University of Basel (Biomedical Engineering) and Clarunis University Digestive Health Care Center, Basel, Switzerland

Task / clinical problem: Grade intraoperative bleeding severity in short clips and use these predictions to estimate total surgery-level blood loss, replacing coarse post-hoc canister or visual estimates.

Category tags: Skill & event assessment (bleeding); Scene understanding & detection. Domain: robotic liver resection.

Method: Bleeding Severity MViT: an MViT-v2-S video backbone with a gated feature refinement module and three fused branches (standard classifier, ordinal branch giving expected severity, and cosine prototype branch), trained with focal loss plus an ordinal SmoothL1 term. A two-stage variant uses a binary bleeding detector (R3D or R(2+1)D) before the severity model. At surgery level, counts of predicted low/medium/high clips feed an MLP predicting EBL class (≤100, 101-600, >600 mL, from Surgical Apgar Score).

Data & evaluation: 66 robotic liver resection videos (139 min mean) with recorded EBL; 25 annotated by two surgeons into 16 s clips (modified VIBe: none/low/medium/high), 11,433 clips (train 17 / val 4 / test 4 patients). Surgery-level MLP trained on the 25 annotated patients, tested on the other 41. Baselines R3D, R(2+1)D, SlowFast, Swin3D, MViT. Metrics: accuracy, per-class accuracy, macro-F1.

Key results: Clip level: best R(2+1)D + BS-MViT* acc 0.633, macro-F1 0.464 (best single baseline R3D 0.439); BS-MViT* alone has best High-class accuracy 0.184 but overall acc 0.510. Surgery level: BS-MViT acc 0.488; two-stage 0.561 (macro-F1 0.398), with 0.000 accuracy on >600 mL. Inter-rater: agreement 0.583, quadratic kappa 0.484.

Strengths: - New clinically grounded task and a patient-level dataset linking clip-level bleeding to recorded blood loss. - Ordinal-aware design matches the structure of the severity scale, and the paper candidly reports inter-rater limits. - Thoughtful two-stage framing for class imbalance.

Limitations / open questions: - Tiny test sets: 4 patients at clip level and only 3 patients >600 mL at surgery level; no seeds or confidence intervals, and differences of 1-3 pp between methods are likely noise. The “best” result is a combination of backbones, and BS-MViT alone does not win overall. - High-bleeding detection is very poor (≤18% accuracy, 38 test clips); macro-F1 below 0.47 is far from clinically usable. The surgery-level MLP is trained on only 25 patients, and 56.1% accuracy lacks a trivial baseline (class prior, op duration, simple regression). - Single centre, single procedure, and bleeding occlusion or irrigation confounds; the claim that this “rethinks” safety assessment overreaches, and external validation is absent.