MICCAI 2026 UNSURE workshop: the 38 accepted papers
Why this page exists
These are the 38 papers accepted at UNSURE, the MICCAI 2026 satellite workshop on uncertainty for safe utilization of machine learning in medical imaging. The list and PDFs come from the MICCAI 2026 satellite open-access site. Each paper gets a short note on the task, method (with the uncertainty construct named), data, key numbers, strengths and limitations. The strengths and limitations are our own reading, not the reviewers’. A companion page covers the SafeSurg workshop.
Categorization
Papers are listed under their main category; some appear twice.
| Category | Papers |
|---|---|
| Segmentation failure detection & quality control | 002 SAM prompt-perturbation · 003 Geometric TTA · 036 Radiomics / DINOv3 distance scores · 038 Surgical failure monitor · 040 SegWithU · 065 Aortic CTA audit · 069 Contrastive uncertainty (pelvic MR) · 079 Label-free OOD thresholds (liver CT) |
| Conformal prediction & risk control | 008 Glioma region-aware RCPS · 010 Quality-stratified conformal · 015 Per-organ recall risk control under shift · 020 Conformal for 3D tumors · 076 Sequential conformal pathways · 077 Bone-age intervals |
| Calibration | 008 Interior/boundary temperature · 013 Mixed-curvature heads · 025 Diffusion qMRI uncertainty · 027 DualTTA for black-box models · 028 ECE does not certify CXR VLMs |
| OOD & anomaly detection | 033 Bayesian anomaly detection · 041 VLM layer selection for OOD · 055 Autoregressive DINOv3 anomaly detection · 062 FetalEDL · (065, 079) |
| Vision-language models | 005 Cardiac MRI reporting · 028 CXR VLM calibration · 041 Zero-shot OOD · 059 Entropy vs paraphrase instability |
| Regression & reconstruction uncertainty | 012 Threshold-aware BMD losses · 019 MRI reconstruction uncertainty · 025 qMRI mapping · 053 Quantile regression for UC scoring · 070 Case-wise AUSE pelvic tilt · 077 Bone age |
| Selective prediction, triage & deferral | 023 Explainable selective classification (urine sediment) · 042 Skin-lesion difficulty across UQ methods · 046 PET-CT QC tiers · 053 · 059 · 062 |
| Label noise, inter-rater variability & metrics | 018 Label noise distorts fairness audits · 024 Presence ambiguity in lung nodules · 031 Inter-rater variability (preclinical MRI) · 058 Spacing-driven metric bias |
| Ensembles & Bayesian methods | 013 · 019 · 029 Training variability as augmentation · 042 · 064 Explanation uncertainty |
| Fairness & robustness auditing | 018 · 035 Counterfactual marginalisation · 046 |
Modalities: brain/abdominal/liver CT and MRI dominate; also chest X-ray, dermoscopy, fetal ultrasound, endoscopy (surgical, UC), fundus/ophthalmology, PET-CT, radiographs (bone age, BMD, pelvis), microscopy (urine sediment), preclinical mouse MRI.
Main themes: 1. Audits that report negative results. Many papers show that a standard signal does not do what it is assumed to do. Calibration error does not certify a VLM (028). Entropy misses presence ambiguity (024). Dilation-based conformal sets are vacuous (020). Whole-case entropy gives no certifiable triage point (008). Mahalanobis distance detects shift but not Dice failures (065). Pooled evaluation rewards site ordering (036). 2. Conformal prediction and risk control are moving to structured outputs and to distribution shift. Examples are per-organ recall (015), instance-level and geodesic sets (020), region-conditional risk (008) and multi-stage clinical pathways (076). Paper 015 shows the guarantees breaking under shift and estimates how many local cases re-certification needs (about 25). 3. Cheap single-pass signals often match ensembles. Examples are prompt perturbation vs test-time augmentation (002), predictive entropy for VLMs (059), SegWithU (040) and quantile regression (053). 4. Frozen foundation features (DINOv3) serve as the representation for failure detection and anomaly detection (036, 055). 5. Uncertainty is tied to a downstream decision. Examples are trial effect sizes (053), fairness gaps (018), radiomic biomarkers (046) and treatment-effect conclusions (031).
Paper summaries
| ID | Title | Category | One-line summary |
|---|---|---|---|
| 002 | When Does Prompt-Perturbation Uncertainty Catch Interactive-Segmentation Failures? (SAM/MedSAM) | Seg. failure | Prompt-perturbation uncertainty ≈ TTA for triage at 1.3× vs 6.8× cost; single-estimate seed SD 0.077 AUROC; under OOD all signals correlate negatively with error. |
| 003 | Beyond Dice: Reliability-Oriented Evaluation of Geometric TTA | Seg. failure | Geometric TTA mainly suppresses boundary outliers (HD95 −21.9 on polyps) rather than raising Dice (+0.02); negligible for pretrained models; saturates at 4 views. |
| 005 | From Generation to Decision: Structure-Aware Reliability for Cardiac MRI Reporting | VLM | Best-of-N scorer + segmentation/retrieval-guided prompting lifts report F1 0.566 → 0.715; single-centre, rule-parsed labels, no abstention eval. |
| 008 | Reliability, Not Accuracy, Is the Bottleneck in Post-Treatment Glioma Segmentation | Calibration; Conformal | Cavity boundaries 3.4–8.3× worse calibrated; two-temperature fix cuts NLL 2.14 → 0.57; region-conditional entropy + RCPS retains 53–68% of cases at risk ≤ 0.25. |
| 010 | Image Segmentation Calibration Based on Estimated Segmentation Quality | Conformal | Stratifying conformal calibration by predicted Dice gives modestly smaller sets at target coverage; gains within noise, calibration sets 42–175. |
| 012 | Threshold-Aware Loss Functions for Opportunistic Osteoporosis Screening | Regression | Threshold-aware + entropy losses raise sensitivity 0.729 → 0.844 and cut near-cutoff false negatives 44%; specificity drops, small test set. |
| 013 | Geometric Diversity: Mixed-Curvature Heads as a Substitute for Ensemble Independence | Ensembles; Calibration | Euclidean + hyperbolic heads decorrelate errors (NLL corr. 0.65 vs 0.93) and halve worst-case calibration error on ISIC; KFAC-Laplace better on average. |
| 015 | Bound-Aware Per-Organ Recall Risk Control under Clinical Domain Shift | Conformal | AMOS-calibrated recall thresholds fail on RAOS for 7/12 organs (duodenum FNR 0.06 → 0.30); re-certification needs ~25 local cases with WSR bound. |
| 018 | Subgroup-Dependent Report-Label Noise Distorts Fairness Audits of CXR Classifiers | Label noise; Fairness | Prediction-powered correction with 2,616 radiologist reads is nearly unbiased and flips 14/43 sensitivity-gap conclusions. |
| 019 | Uncertainty Estimation in DL MRI Reconstruction with Focus on Pathologies | Reconstruction | Model ensembles track reconstruction error in pathology boxes (ρ 0.80–0.83); Jacobian-sketch perturbation does not; pathology-aware training adds nothing. |
| 020 | Beyond Morphological Dilation: Revisiting Conformal Prediction for 3D Tumor Segmentation | Conformal | Dilation CP is operationally vacuous on BraTS; instance-level + geodesic CP fixes it with 45% smaller enhancing-tumor sets. |
| 023 | Example-based Explainable Selective Classification with GNNs (urine sediment) | Selective; XAI | GAT over retrieved references + explainer-weighted rejection: F1 0.989 at 95% coverage; AUROC below softmax, 268 test images. |
| 024 | Aggregated Aleatoric Uncertainty Fails to Capture Presence Ambiguity (lung nodules) | Label noise; Seg. | Entropy is near-random for presence ambiguity (AUROC ≤ 0.58); supervised ambiguity head gets 0.74 LIDC / 0.67 external LNDb. |
| 025 | Evaluating and Calibrating Diffusion-derived Uncertainty for Quantitative MRI | Reconstruction; Calibration | Diffusion uncertainty ranks errors (AUROC 0.77 T1, 0.95 T2) but is miscalibrated; bias + scale correction cuts calibration error ~5×; synthetic BrainWeb only. |
| 027 | Improving Calibration of Black-Box Radiology AI Using Test-Time Augmentation | Calibration | Learned TTA weighting (DualTTA) cuts ECE 54% for PE, 43% for ICH; beats TS/MC dropout/ensembles on PE only. |
| 028 | Well-Calibrated but Unusable: Calibration Error Does Not Certify Zero-Shot CXR VLMs | Calibration; VLM | Post-hoc calibration hits an ECE floor ~0.08–0.10 regardless of AUROC; a below-chance ranker reaches ECE 0.029. |
| 029 | Uncertain but Useful: Leveraging CNN Training Variability into Data Augmentation | Ensembles | FastSurfer seed variability tracks numerical (MCA) variability (ρ 0.88); used as augmentation improves brain-age MAE in-domain but not on external HBN. |
| 031 | Does Inter-Rater Variability Matter? Preclinical MRI Tumor Segmentation | Inter-rater | Three raters, 164 mouse scans: Dice 0.92–0.95, ICC 0.97; rater biases (−13/+29 mm³) do not change treatment-effect conclusions. |
| 033 | A Principled Approach to Unsupervised Anomaly Detection | OOD/anomaly | Anomaly detection as Bayesian corruption inference recovers PaDiM/CFLOW-AD; +2.3 AUROC on MVTec; 38.0 Dice on ATLAS (2nd); single seed. |
| 035 | Counterfactual Marginalisation: Evaluating Robustness to Nuisance Variables | Fairness | Causal-generator counterfactuals over sex/age detect injected bias better than standard risk; validated only on synthetic bias. |
| 036 | Foundation Model and Radiomics Distance Scores for Post-Hoc Segmentation Failure Detection | Seg. failure | Mahalanobis on mask radiomics / DINOv3 matches ensembles within-site; shows pooled multi-site evaluation rewards site ordering. |
| 038 | Beyond Uncertainty: Failure Monitoring for Surgical Segmentation under Degradation | Seg. failure; Conformal | 22-feature XGBoost monitor + Mondrian conformal: LOCO AUROC 0.81 vs entropy 0.48; 40% false alarms at severity 3; loses to entropy on SAM2. |
| 040 | SegWithU: Deterministic Perturbation Probes for Risk-Aware Segmentation | Seg. failure; Calibration | Frozen-backbone probe head beats 5-model ensembles on voxel AUROC/AURC at ~7× lower runtime; voxel-level eval, LiTS only 10 test cases. |
| 041 | Layer Selection in VLMs for Zero-Shot OOD Detection | OOD; VLM | Multi-resolution entropy picks intermediate layers: OASIS near-OOD AUROC 100 vs 55; MIDOG still near chance; mixed on BioMedCLIP. |
| 042 | Uncertainty Identifies Difficult Samples Across Methods (skin lesions) | Ensembles; Selective | Five UQ methods agree on hard cases (ρ 0.54–0.91); deferring 20% cuts error 7.4% → 2.5%; confident errors missed; Fitzpatrick VI nearly absent. |
| 046 | Confidence-Tiered Quality Control for Radiomic Biomarkers in Multicentre PET-CT | Fairness; Selective | Rule-based PASS/WARN/FAIL flags 40% of 130 scans; apparent pCR AUC gain (0.52 → 0.66) not separable from centre/vendor mix (P = 0.10). |
| 053 | Quantile Regression for Uncertainty-Aware Endoscopic Scoring in UC Trials | Regression; Selective | Interval-width deferral (15%) raises trial effect size g 0.73 → 0.81 on an unseen trial vs 0.66 for random deferral. |
| 055 | Spatial Autoregressive Modeling of DINOv3 Embeddings for Anomaly Detection | OOD/anomaly | Single-pass, 14 ms; BraTS AUPR 73.9 but 4th on liver CT (8.6 vs 25.3); slice-level BMAD with labelling bias. |
| 058 | When Voxels Are Not Equal: Spacing-Driven Metric Bias in Segmentation | Metrics | On KiTS23, voxel-space boundary Dice favours thick slices (+0.031) but physical-space flips sign (−0.011); aggregation choice moves cyst Dice 0.24 → 0.49. |
| 059 | Predictive Entropy as a Joint Screen for Error and Paraphrase Instability in Medical VLMs | VLM; Selective | Single-pass entropy predicts paraphrase flips (AUROC 0.82); 80% coverage cuts error 8.6% → 3.3%; MC dropout/ensembles add nothing. |
| 062 | FetalEDL: OOD-Aware Evidential Deep Learning for Fetal Ultrasound Planes | OOD; Selective | Evidential ConvNeXt with near-OOD sampling: OOD AUROC 0.991 vs ~0.91; abstaining on 2.2% lifts accuracy 96.9% → 97.9%. |
| 064 | Explanation Uncertainty in the Classification of Pulmonary Nodules | XAI; Ensembles | Ensemble saliency mean/SD on 751 LIDC nodules; explanation uncertainty uncorrelated with prediction entropy (abs r ≤ 0.19). |
| 065 | Complementary Reliability Axes for Aortic CTA Segmentation | Seg. failure; OOD | Mahalanobis detects OOD (AUROC 0.85) but not Dice; pairwise MC-dropout Dice and centerline degeneracy catch failures; fusion doesn’t help. |
| 069 | Contrastive Uncertainty Learning for Lower-Pelvic MR Segmentation | Seg.; Ensembles | Entropy-chosen contrastive anchors: Dice flat (0.834), surface distance 1.61 → 1.42 mm; HD95 not significant. |
| 070 | Case-wise AUSE for Detecting Failures in 3D Pelvic Tilt Estimation | Regression | Case-wise ROI-AUSE detects outliers at AUROC 0.90 vs 0.53 for mean uncertainty, but needs GT depth; reference-free surrogate 0.67. |
| 076 | Sequential Conformal Safety for Clinical Decision Pathways in Ophthalmology | Conformal | Stage-wise conformal pruning with union-bound α keeps a guideline-safe pathway 96.5–99.5% at α = 0.10; simulated workflows; up to 55% unsafe exposure. |
| 077 | Uncertainty-Aware Bone Age Assessment: Conformal vs Bayesian | Regression; Conformal | Conformal variants hit nominal coverage; MC dropout under-covers by 7–11 pts; BNN intervals 1.5–2× wider. |
| 079 | Label-Free Threshold Selection for OOD Detection in Liver CT Segmentation | OOD; Seg. failure | Log-t fit on 400 unlabelled scans sets risk tiers: 100% sens / 79% spec (Medium+High); only 18 failures among 500 test scans. |
Recurring weaknesses (our own critical read)
- Small calibration or test sets, few failures: 010 (calibration sets of 42–175), 023 (268 test images), 040 (LiTS, 10 cases), 079 (18 failures), 012 (312 test cases). Coverage and AUROC claims carry wide intervals that are seldom reported.
- Synthetic or simulated validation only: 025 (BrainWeb), 035 (injected bias), 076 (simulated pathways).
- Exchangeability is assumed but not tested. Most conformal papers calibrate and test on splits of the same data. Paper 015 shows what happens under real shift, and that lesson applies to the others.
- Gains within noise or inconsistent across backbones/datasets: 002 (seed SD 0.077), 010, 012, 013 (DERM12345), 029 (external set), 041 (MIDOG).
- Evaluation at the wrong unit: voxel-level rather than case-level failure detection (040), slice-level anomaly benchmarks (055), and pooled multi-site evaluation (identified as a problem by 036).
- Single-centre data or confounding: 005 and 046, where the apparent gain cannot be separated from centre/vendor composition.
Paper notes
002 · When Does Prompt-Perturbation Uncertainty Catch Interactive-Segmentation Failures? An Empirical Study on SAM/MedSAM
Authors (first/last): Sathvik Loke / Suhrit Bestavemula · Affiliation: Illinois Mathematics and Science Academy; Neuqua Valley High School (Illinois, USA)
Task / clinical problem: Telling a clinician when a mask returned by a promptable foundation segmenter (SAM, MedSAM) should not be trusted, without training or labels.
Category tags: Segmentation uncertainty & failure detection; Ensembles & Bayesian methods. Modality: endoscopy (RGB), dermoscopy, brain MRI (2D slices); polyp, skin lesion and hippocampus segmentation.
Method: Prompt-perturbation uncertainty (PPU) jitters the click/box K times (default K=16, sigma=0.08 of object diagonal), decodes K masks against one cached image embedding, and uses 1 minus mean pairwise IoU as a case-level reliability score and Bernoulli entropy of the mean probability map as a spatial map. Cases whose score exceeds a threshold are flagged as catastrophic failures (Dice < 0.3). It is benchmarked against softmax entropy, SAM’s own iou-prediction head, and dihedral (D4) test-time augmentation. Comparisons use paired DeLong and permutation tests with Holm correction, plus a hyperparameter sweep and non-oracle (off-centroid click, loose box) prompts.
Data & evaluation: Kvasir-SEG (N=200), ISIC-2018 (N=100), MSD Hippocampus (N=100, 2D slices); SAM ViT-B, ViT-L, MedSAM (box only); 10 dataset/backbone/prompt cells. Metrics: failure-flag AUROC, Spearman rho of uncertainty vs 1-Dice, pixel-error AUROC, compute cost.
Key results: - Almost no PPU vs baseline difference survives Holm correction; e.g. SAM-B Kvasir box AUROC .96 (PPU) vs .94 softmax, .96 iou, .95 TTA. - Seed noise of one PPU estimate is SD 0.077 AUROC (range 0.63-0.81 over 5 redraws), and number of “failures” varies 8-13. - Pixel-level localisation: PPU weakest (SAM/Kvasir/point 0.677 vs softmax 0.723, TTA 0.747). - iou head fails on MedSAM/Kvasir: rho +0.03 vs PPU +0.75 (significant). - OOD hippocampus point prompt (Dice 0.31, 44/100 failures): all signals negatively correlated with error (PPU -0.39, softmax -0.23, iou -0.39, TTA -0.35). - Cost: PPU 1.3x a single prediction vs TTA 6.8x (encoder 1.19 s vs decoder 45 ms).
Strengths: - Honest, self-correcting negative-results paper: paired tests, multiplicity control, withdrawal of an earlier claim. - Measures seed variance of the estimator itself and tests non-oracle prompts, both rarely done. - The “all signals invert out of distribution” finding is a clear safety warning.
Limitations / open questions: - Very small cells (0-44 failures, one with zero), so the study is underpowered to rank methods; mostly “no detectable difference”. - Realistic prompts are simulated, not logged clinician prompts; only 2D, three datasets, one MedSAM model. - No calibration or decision-level (coverage/risk) evaluation, and no trained baselines (e.g. UncertainSAM, Laplace); jitter scale cannot be tuned label-free.
003 · Beyond Dice: A Reliability-Oriented Evaluation of Geometric Test-Time Augmentation in Medical Image Segmentation
Authors (first/last): Subhash Kashyap (sole author) · Affiliation: National Institute of Technology Rourkela, India
Task / clinical problem: Does geometric test-time augmentation (TTA) make segmentation more reliable by suppressing rare, clinically costly boundary failures, beyond what Dice captures?
Category tags: Segmentation uncertainty & failure detection; Ensembles & Bayesian methods. Modality: colonoscopy (RGB) and brain MRI (3D); polyp segmentation, BraTS enhancing-tumour segmentation.
Method: Deterministic flip/rotation TTA with 2, 4 or 8 views: each transformed input is passed through the unchanged model, predictions are inverted to the original frame, averaged into a consensus probability map and then thresholded. The study evaluates only the aggregated consensus, not view-wise disagreement as an uncertainty map, so TTA is treated as a reliability mechanism rather than a decision rule. Differences from single-pass inference are tested with paired two-tailed t-tests on per-case metrics, using HD95 as the main “failure” metric alongside Dice and boundary F1.
Data & evaluation: CVC-ClinicDB (2D polyp) with a pretrained ResNet50-UNet and a from-scratch SwinUNETR; BraTS 2021 enhancing tumour with SegResNet. Metrics Dice, BF1, HD95; view-count ablation; qualitative examples. Dataset sizes and splits are not stated in the text. No MC-dropout/ensemble baselines.
Key results: 8-view TTA vs single pass: - UNet/CVC: dDice -0.005 (ns), dBF1 +0.026, dHD95 -7.0. - SwinUNETR/CVC: dDice +0.020, dBF1 +0.043, dHD95 -21.9*. - SegResNet/BraTS: dDice +0.0015, dHD95 -0.70, all non-significant. - 4 views capture nearly all of the gain; median improvements are small but the HD95 upper tail is compressed.
Strengths: - Useful reframing: evaluate TTA on tail/boundary metrics rather than mean Dice. - Honest scoping; limitations are stated explicitly and conclusions hedged. - Code released; view-count ablation gives practical guidance.
Limitations / open questions: - Only three models, two datasets, in-distribution test data; the “gains larger for weaker models” claim rests on a single from-scratch model that also differs in architecture and pretraining (confounded). - Not really uncertainty quantification: no TTA-disagreement maps, no failure-detection AUROC, calibration or selective-prediction analysis, and no MC-dropout/ensemble comparison. - No test-set sizes, multiplicity correction across many metric tests, effect-size CIs, or latency/memory measurements, so the “efficient 4-view” claim is qualitative; HD95 differences may be driven by a few outlier cases.
005 · From Generation to Decision: Structure-Aware Reliability for Cardiac MRI Reporting
Authors (first/last): Minxuan Xu / Chengyan Wang · Affiliation: Fudan University (Human Phenome Institute etc.); GE HealthCare Beijing; Ruijin Hospital, Shanghai Jiao Tong University
Task / clinical problem: Making VLM-generated cardiac MRI reports anatomically consistent at the myocardial-segment level, given stochastic decoding and no way to verify a single sampled report.
Category tags: Vision-language models; Selective prediction & triage. Modality: cardiac T2-weighted MRI (short-axis); myocardial segment-level abnormality reporting (AHA segments).
Method: Stage I conditions a VLM on segmentation-derived anatomical guidance (LV/RV/myocardium masks, AHA segment partitions) plus top-2 retrieved similar image-report pairs, then samples N candidate reports (“preference-neighbourhood sampling”). Stage II is a learned best-of-N selector: a BioMedCLIP-initialised cross-attention scorer predicts each candidate’s segment-level consistency, trained with a joint regression (distance of segment precision/recall to (1,1)) and within-case ranking loss. The report with the highest predicted score is output; there is no abstention threshold or conformal guarantee, and “uncertainty” is operationalised as candidate-pool variance and learned quality scores.
Data & evaluation: 750 patients, 6,237 short-axis images with structured reports, patient-level split; retrieval set from 120 patients; scorer trained about 10 epochs on about 5,000 ordered groups. Metrics: segment-level precision/recall/F1 and macro segment AUC from rule-parsed segment vectors. Baselines: RadFM, LLaVA-Med, zero-shot Gemini-3-Flash/Pro; backbones ChatGPT-5, Qwen-VL-Max; random and similarity-based selection; 20% expert audit of labels.
Key results: - Gemini-3-Pro: F1 0.566 to 0.715, AUC 0.662 to 0.764; Gemini-3-Flash: F1 0.341 to 0.656, AUC 0.471 to 0.711. - RadFM AUC 0.539, LLaVA-Med 0.561. - AUC gains across backbones: ChatGPT-5 +0.112, Qwen-VL-Max +0.107, Flash +0.240, Pro +0.102. - Ablation: removing ranking loss F1 0.601, removing regression 0.591, removing structure supervision 0.593. - Audited labels give consistent gains (Pro F1 0.556 to 0.729).
Strengths: - Practical reliability layer that is generator-agnostic and works on top of black-box VLMs. - Segment-level, anatomy-grounded supervision and evaluation rather than BLEU/ROUGE; expert audit of parsed labels. - Clear ablations and oracle-gap analysis of candidate-pool quality.
Limitations / open questions: - Single-centre dataset; no external validation. Selection is not calibrated or abstention-capable: no coverage/risk analysis, no ECE, and “reliability” is mostly accuracy gain from best-of-N, not uncertainty quantification. - Label noise: rule-based parsing of the same report templates for training and testing; only a 20% audit, and the scorer is trained on the generator’s own outputs, so it may not transfer to different generators or sampling temperatures; no variance/significance tests. - Comparisons are unequal (zero-shot general VLMs vs a pipeline with retrieval and trained scorer); inference cost of N samples, and the clinical meaning of F1 0.7 for segment-level findings, are not discussed.
008 · Reliability, Not Accuracy, Is the Bottleneck in AI-assisted Post-Treatment Glioma Segmentation: Region-Aware Recalibration and Risk-Controlled Triage
Authors (first/last): Mostafa Abdalla Mostafa Badr / Reda Abdelwahab Ahmed El-Khoribi · Affiliation: Cairo University (Faculty of Graduate Studies for Statistical Research; Faculty of Computers and AI), Egypt
Task / clinical problem: Trustworthy probabilities and case-level triage for post-treatment glioma segmentation, especially the resection-cavity rim that drives progression vs treatment-effect decisions (RANO 2.0).
Category tags: Calibration; Conformal prediction & risk control. Modality: multi-parametric brain MRI (BraTS-GLI post-treatment); tumour sub-regions (WT/TC/ET) and resection cavity.
Method: Uses the released BraTS 2024 winning checkpoints (nnU-Net, MedNeXt, Swin UNETR, 5 folds each, plus a 30-fold cross-architecture ensemble) with no retraining. Calibration is measured region-conditionally, split into a one-voxel boundary shell vs interior. A two-parameter interior/boundary temperature scaling fixes probabilities but, being monotone, cannot change thresholded masks or triage ranking. For triage, per-case mean predictive entropy over the predicted cavity voxels (region-conditional) is compared with whole-tumour entropy; deferral thresholds are selected with distribution-free risk control (RCPS/Learn-then-Test, Hoeffding-Bentkus, delta=0.10) on risk = 1 - cavity Dice.
Data & evaluation: 271-case BraTS-GLI post-treatment “additional training” partition as temporally separated held-out set (194 cavity-bearing cases, 90 patients); patient-level 136/135 fit/report split; patient-level bootstrap CIs, Wilcoxon + BH; 200 random patient splits for guarantee transfer. Metrics: ECE, Brier, NLL, AURC, retention at target risk.
Key results: - Dice saturated (architectures within about 1 point); cavity is worst calibrated (single-model ECE 0.146-0.182; ensemble 0.130). - Boundary ECE is 3.4-8.3x interior; cavity boundary vs interior ECE 0.351 vs 0.104. - Interior/boundary temperature: cavity NLL 2.14 to 0.57, Brier 0.225 to 0.176, beating a global scalar (Brier +0.010); ECE gain not significant. - Whole-case entropy AURC 0.34/0.35/0.39 exceeds keep-all 0.302/0.309/0.324 (certifies nothing); region-aware AURC 0.20/0.23/0.16, retaining 68/62/53% of cases at risk <= 0.25; guarantee holds on 93.5/91.5/84.5% of held-out splits (nnU-Net/Swin/MedNeXt).
Strengths: - Clear, operationally useful separation of calibration from decision safety (monotone maps cannot change thresholded decisions). - Rigorous patient-level resampling and a held-out set that does not overlap the checkpoints’ training data; a negative control (whole-case signal) is included. - Honest about the weakest cases (small cavities, MedNeXt at 84.5% below the 90% target).
Limitations / open questions: - Cavity cohort selection (GT volume >= 0.5 mL) and the boundary/interior split use ground truth, unavailable at deployment; predicted proxies are unvalidated. - Single in-distribution dataset (BraTS ecosystem), 90 patients in the triage cohort; the risk-control guarantee is on the mean and assumes exchangeability between calibration and test patients, and the 50% coverage floor choice is ad hoc; no external or multi-site shift tested. - Risk target 0.25 is justified by inter-rater overlap but no clinician-in-the-loop evaluation; ECE improvement not significant, and no comparison with other deferral scores (e.g. MC/ensemble variance, volume baseline) beyond whole-tumour entropy.
010 · Image Segmentation Calibration Based on Estimated Segmentation Quality
Authors (first/last): Rotem Nizhar / Jacob Goldberger · Affiliation: Faculty of Engineering, Bar-Ilan University, Israel
Task / clinical problem: Producing conformal segmentation prediction sets with guaranteed foreground coverage that are not needlessly large on easy cases.
Category tags: Conformal prediction & risk control; Segmentation uncertainty & failure detection. Modality: breast ultrasound (BUSI) and colonoscopy/endoscopy polyp images; lesion/polyp binary segmentation.
Method: A wrapper around existing conformal segmentation methods (CPS, mask-dilation; CRC, pixel-threshold risk control). Part of the calibration set (100-150 images) trains an auxiliary ResNet18 or ConvNeXt network that predicts Dice from the image and predicted mask; the remaining calibration images are split by predicted Dice at a fixed cutoff d=0.6 and a separate conformal threshold (q1 for hard, q2 for easy) is calibrated per group, then used according to the test image’s predicted Dice. This is a learned Mondrian partition; the guarantee holds because the partition is label-independent and d is fixed in advance. Target: P(|Y cap C|/|Y| >= tau) >= 1 - alpha.
Data & evaluation: BUSI (calibration/test sizes 42), Kvasir (106), composite Polyps with PraNet (175); U-Net and PraNet base models; 36 random calibration/test reshuffles; samples with base prediction < 350 pixels excluded. Metrics: empirical coverage and “stretch” (|C|/|prediction|); baselines CPS, CRC.
Key results: - Coverage stays near or above the nominal level (e.g. 0.92-0.97), with a modest drop vs baseline (e.g. BUSI CPS 0.96 to 0.93). - Stretch gains are small but fairly consistent: Kvasir CPS 4.34 to 3.58 (BUSI ResNet18, alpha .1, tau .9), Kvasir CRC 3.04 to 2.72; some cells are unchanged (Polyps ~1.04). - BUSI CRC stretch about 20 vs 20 (negligible change). - Dice predictor MAE 0.03-0.12 (ConvNeXt 0.03 on Kvasir/Polyps); splitting threshold 0.5-0.7 stable; 3+ bins not better.
Strengths: - Simple, modular, plug-in method with a clean exchangeability argument and public code. - Link between predicted segmentation quality and conformal efficiency is intuitive. - Sensitivity checks on cutoff and number of bins, repeated over 36 splits.
Limitations / open questions: - Gains are marginal relative to the reported std (often within 1 SD), no significance tests; cells like BUSI CRC and Polyps CPS show almost none, and coverage sometimes falls slightly. - Very small calibration sets (42/106/175) with 100-150 images consumed by the Dice predictor; the extreme “stretch” values for CRC (about 20x) suggest a weak base calibration, and polyp/breast datasets are all single-class 2D with exclusions that change the test distribution. - Coverage is marginal within groups of a learned partition, not conditional per image; no multi-class, 3D, or distribution-shift tests, and the fixed cutoff d=0.6 was tuned on the test splits (sensitivity table), which weakens the claim that it was predefined.
012 · Not All Errors Are Equal: Threshold-Aware Loss Functions for Opportunistic Osteoporosis Screening
Authors (first/last): Mohammad Al-Fawa’reh / Martin Masek · Affiliation: Centre for AI and Machine Learning (CAIML), Edith Cowan University, Western Australia
Task / clinical problem: Opportunistic osteoporosis screening by predicting femoral-neck BMD (and low-BMD status, T-score < -1) from distal-radius radiographs, where errors near the diagnostic cutoff matter most and false negatives are costly.
Category tags: Regression & reconstruction uncertainty; Selective prediction & triage. Modality: plain radiograph (distal radius, X-ray); BMD regression with threshold-derived classification.
Method: Two training losses on a shared-backbone, dual-head network (DenseNet121/ResNet34/Swin-T) that outputs a BMD mean, log-variance (heteroscedastic regression) and a normal/abnormal logit. TAML multiplies squared error by a Gaussian bump around the clinical thresholds and by an asymmetric factor for predicting “healthier than actual”. UPIL adds a hinge penalty when the product of predicted standard deviation and classification entropy falls below a margin that grows near the threshold, discouraging joint overconfidence. The decision is the thresholded BMD/T-score; uncertainty is used only as a training regulariser, not at inference.
Data & evaluation: 1,040 radiograph-DXA pairs (500 Perth hospitals, 540 OAI), 728 train / 312 test (96 abnormal in test); 3-fold CV on training for selection. Metrics: MAE, sensitivity, specificity, F1, AUC; quartile “zones” by distance to the T=-1 cut-off; MSE and multi-task MSE baselines.
Key results: - Single-task, TAML vs MSE: DenseNet121 sensitivity 0.729 to 0.844, Swin-T +12.2 pp; specificity -3 to -6 pp; ResNet34 MAE worsens (0.097 to 0.109). - Zone A (closest quartile of 78): accuracy 64.1 to 73.1%, false negatives 16 to 9 (-43.8%). - Multi-task DenseNet121 TAML+UPIL: F1 0.802 to 0.852, AUC 0.947 to 0.952, MAE 0.106 to 0.093; UPIL alone raises ResNet34 sensitivity 0.645 to 0.841. - Swin-T multi-task: F1 0.834 to 0.848 (small).
Strengths: - Clearly motivated, simple, drop-in losses aligned with threshold-driven decisions; sensible zone analysis showing where gains occur. - Reports trade-offs (specificity loss, non-uniform backbone effects) rather than only wins. - Combines heteroscedastic regression with a decision-aware penalty.
Limitations / open questions: - Small test set (312, 96 positives) with single split and no seeds, CIs or significance tests; improvements like AUC (+0.005) or Swin F1 (+0.014) are within noise, and results are inconsistent across backbones (ResNet34 MAE and AUC degrade under TAML). - Sensitivity gain largely reflects a shifted operating point from asymmetric weighting (could be matched by moving the decision threshold); no comparison with that or with cost-sensitive/focal/ordinal losses, and loss hyper-parameters were not tuned per method. - UPIL’s “uncertainty principle” motivation is heuristic; the predicted variance is never evaluated for calibration or used for abstention, so little actual uncertainty evaluation; single mixed cohort without external validation.
013 · Geometric Diversity: Mixed-Curvature Heads as a Substitute for Ensemble Independence
Authors (first/last): Peter J.T. Kampen / Anders Nymark Christensen · Affiliation: Technical University of Denmark (DTU); Novo Nordisk A/S (one author)
Task / clinical problem: Getting well-calibrated, diversity-based uncertainty for medical image classifiers without the cost of training several independent networks.
Category tags: Ensembles & Bayesian methods; Calibration. Modality: dermoscopy (ISIC 2019, DERM12345) and retinal fundus (RetinaMNIST); multi-class lesion / disease-grade classification.
Method: On a frozen fine-tuned ConvNeXt-tiny backbone with its Euclidean head, add one extra head operating on the Lorentz (hyperbolic) manifold that classifies by negative geodesic distance to fixed prototypes placed from the class hierarchy. The two heads’ logits are averaged (a geometric-mean ensemble), and the cross-entropy ambiguity decomposition (Bhattacharyya distance for m=2) explains why decorrelated, equally competent heads improve proper scores. Control: a second Euclidean head (“Dual-Euc”). The calibrated probability from the fused logits is the output; diversity is quantified by inter-head per-sample NLL correlation, and members can be further ensembled over 5 backbones.
Data & evaluation: ISIC 2019 (25,331 train+val / 6,191 test, 8 classes), DERM12345 (10,602 / 1,698, 18 classes, imbalance 2,378), RetinaMNIST (1,200 / 400, 5 classes); 5 seeds, paired t-tests. Metrics: ECE, MCE, ACE, macro ACE, NLL, balanced accuracy. Baselines: Dual-Euc, individual heads, KFAC Laplace, standard deep ensembles up to M=5.
Key results: - MCE significantly lower than Dual-Euc in all datasets: ISIC 0.229 vs 0.462, DERM12345 0.187 vs 0.243, Retina 0.271 vs 0.405. - ISIC ECE 0.093 vs 0.217 (Dual-Euc); inter-head NLL correlation 0.648 vs 0.925. But Laplace is better on ISIC ECE (0.045) and NLL (0.881 vs 1.204). - DERM12345: ECE 0.040 vs 0.046 (small), hyperbolic head alone has NLL 1.18 vs 0.59 so equal-competence breaks down; correlation drops only 0.907 to 0.825. - Balanced accuracy gain small (ISIC 0.595 vs 0.576). Mixed ensembles beat standard ensembles on ISIC, mixed results elsewhere (worse NLL on DERM12345).
Strengths: - Clean, controlled comparison (matched Dual-Euc control) with a principled ambiguity-decomposition explanation and measured decorrelation. - Reports negative or mixed results (Laplace better on average metrics, DERM12345 behavior) and uses worst-case calibration (MCE) as a clinically meaningful lens. - Multiple seeds, three datasets, two modalities, code available.
Limitations / open questions: - MCE is a single-bin, binning-sensitive statistic that carries the headline claim; the average calibration win is inconsistent and Laplace beats it on ISIC. - Only classification on a frozen backbone, 5 seeds, no OOD/shift or selective-prediction evaluation, so the claimed “substitute for ensemble independence” is untested where independent ensembles matter most; heads share one backbone so diversity is limited (correlation still 0.65-0.83). - Hyperbolic prototypes tied to a (shallow) class hierarchy and a low d=15; gains depend on dataset/label-space size (weakest for 18 classes), and no compute comparison or combination with Laplace/temperature scaling is shown.
015 · Bound-Aware Per-Organ Recall Risk Control for Multi-Organ CT Segmentation under Clinical Domain Shift
Authors (first/last): Souraj Adhikary / Andre Mastmeyer · Affiliation: Department of Engineering Sciences, Jade Hochschule Wilhelmshaven, Germany
Task / clinical problem: Guaranteeing per-organ recall (organs-at-risk for radiotherapy/surgical planning) of a frozen multi-organ CT segmenter, and finding how many local labelled cases are needed to re-certify the guarantee after clinical domain shift.
Category tags: Conformal prediction & risk control; OOD & anomaly detection. Modality: abdominal CT; 12-organ segmentation (AMOS to RAOS shift).
Method: For each organ, a softmax threshold tau_k is chosen so that the population-mean voxel false-negative rate (1 - recall, computed only where the organ is present) is <= alpha. Three rules are compared: RCPS with a Hoeffding-Bentkus (HB) bound, RCPS with the variance-adaptive Waudby-Smith-Ramdas (WSR) betting bound (both high-probability, delta=0.10), and Conformal Risk Control (CRC, expectation only). Thresholds are calibrated on AMOS (out-of-fold softmax of an nnU-Net), frozen and audited on RAOS, then re-certified on n local RAOS cases; a “usable” threshold must also reach mean precision >= 0.5 (illustrative criterion), since low thresholds can predict everything.
Data & evaluation: nnU-Net trained on AMOS CT (236 usable cases; 150/86 calibration/test, 20 seeds); RAOS shifted cohort of 163 cases (oncology, partial/full excision); alpha in {0.05, 0.10}; 200 re-certification draws per budget; 2000 bootstrap resamples. Baselines: fixed tau=0.5, global threshold.
Key results: - In-distribution control passes (realized FNR <= alpha in >= 95% of splits; mean FNR 0.028); fixed tau=0.5 violates 6-8/12 organs, one global threshold 5-6/12. - Transfer: 7/12 organs exceed alpha=0.10 on RAOS (6/12 at 0.05); duodenum FNR 0.063 to 0.297, right kidney 0.064 to 0.143; both adrenals get vacuous threshold 0. - Re-certifying six “Tier-1” organs needs 25 local cases with WSR vs 30-40 with HB; CRC 10-15 cases but up to 17.4% of individual cases exceed alpha (p99 0.92). No Tier-2 organ meets precision >= 0.5 at 25 cases. - Bonferroni delta/12 for simultaneous control roughly doubles the budget.
Strengths: - Realistic, transparent audit of conformal guarantees under shift; explicit about what each guarantee means (marginal, per-organ, population mean vs per-patient). - Reports false-positive cost and vacuous thresholds, not only recall; bound choice (HB vs WSR vs CRC) is shown to affect annotation budget. - Positive in-distribution control and matched-fold checks.
Limitations / open questions: - Single model and a single source/target pair, one site for re-certification, so budget estimates are optimistic and have no confidence intervals; calibration predictor (out-of-fold) differs from deployment ensemble, so the formal guarantee does not strictly apply. - Precision >= 0.5 “usability” cutoff is arbitrary (not clinically validated) and defines the Tier-1/2 split; only recall on organs known to be present is controlled (no hallucination, resection, or per-patient guarantees), and marginal per-organ control. - No comparison with retraining, domain adaptation, importance-weighted/shift-robust conformal methods, or other uncertainty scores; shift cause is not attributed (surgical ladder flat).
018 · Subgroup-Dependent Report-Label Noise Distorts Fairness Audits of Chest X-ray Classifiers: A Prediction-Powered Correction
Authors (first/last): Han-Jay Shu / Julian C. Hong · Affiliation: UCSF (Bakar Computational Health Sciences Institute; Epidemiology & Biostatistics; Radiation Oncology)
Task / clinical problem: Auditing subgroup fairness of chest X-ray classifiers when the evaluation labels (NLP-extracted from radiology reports) systematically under-report findings visible on the image.
Category tags: Label noise, inter-rater variability & metrics; Fairness & robustness auditing. Modality: chest X-ray (MIMIC-CXR, REFLACX image reads); 11 findings, subgroups by sex, age, race, view.
Method: A logistic-regression classifier on frozen RAD-DINO embeddings is trained on CheXpert report labels only. Evaluation uses prediction-powered inference (PPI++): a small radiologist image-read anchor (REFLACX, n=2,616 images) provides a “rectifier” (truth vs report label) that corrects the four confusion-cell rates estimated on abundant report-labeled data; sensitivity, specificity, prevalence and subgroup gaps are derived, with patient-level cluster-bootstrap 95% CIs. The prediction is never altered; uncertainty is in the evaluation estimate, and a “flip” is a gap whose sign or significance changes between naive and corrected audits. Validated by 100 patient-disjoint 50/50 splits within the anchor.
Data & evaluation: Training 271,325 MIMIC-CXR images; anchor 2,616 images (2,199 patients); held-out 68,372 images (illustrative only); subgroup cells require >= 20 image-positive cases. Baseline is naive evaluation against report labels; true value is evaluation against image read.
Key results: - Report labels are under-report dominated (FNR 0.35-0.98 vs FPR 0.006-0.21); consolidation report prevalence 0.050 vs image 0.259. - Classifier AUROC vs image read >= AUROC vs report labels for 6 of 11 findings (cardiomegaly +0.097). - Naive specificity understated by up to 0.12; PPI++ bias <= 0.009 with coverage 0.94-1.00; recovers prevalence (0.050 to 0.258, true 0.259). - Naive sensitivity bias ranges -0.047 to +0.094 across subgroups; 14 of 43 gap conclusions flip (14-24 across thresholds 0.3-0.7); gap error falls 0.071 to 0.042. E.g. age cardiomegaly gap -0.26 becomes -0.007 (n.s.).
Strengths: - Important, concrete demonstration that evaluation-label noise can manufacture or mask fairness gaps, with a principled, statistically valid fix. - Within-anchor validation, threshold sweep, and a reader-noise bound from the five-reader subset. - Honest about coverage failures and exploratory subgroup cells.
Limitations / open questions: - “Truth” is a single-reader, certainty-thresholded image read (some REFLACX sets); validity shown only within the anchor distribution, with a deployment-scale estimate resting on an unverifiable transfer assumption and distribution differences (view). - Small subgroups: coverage falls to 0.51 in sparse cells, race analyses are exploratory (2 findings), PPI++ variance can exceed the naive error where bias nearly cancels; many gap tests with no multiplicity correction, and anchor size was not varied. - Only one simple classifier (logistic head on frozen RAD-DINO) and CheXpert labels; the model’s own fairness is not addressed and findings with mapping artifacts (consolidation, pleural other) are not corrected.
019 · Uncertainty Estimation in Deep Learning MRI Reconstruction with Focus on Pathologies
Authors (first/last): Vanya Saksena / Bernhard Kainz · Affiliation: Friedrich-Alexander-Universitat Erlangen-Nurnberg, Germany; Imperial College London, UK
Task / clinical problem: Checking whether uncertainty maps from accelerated-MRI deep reconstruction flag errors inside diagnostically relevant pathology regions (hallucinated or removed findings), not just in global image quality.
Category tags: Regression & reconstruction uncertainty; Ensembles & Bayesian methods. Modality: brain MRI (multi-coil k-space, fastMRI+); undersampled reconstruction (R=4, 8) evaluated on expert pathology bounding boxes.
Method: Two uncertainty constructs, both a pixel-wise sample variance of reconstructions. (1) Model ensemble (ME) of six End-to-End VarNets with different pathology exposure (geometric augmentation, synthetic anomaly blending, and a segmentation-guided Dice+SSIM “ROIrecon” loss using a frozen nnU-Net on bounding-box weak labels); a vanilla ensemble of 5 seeds (MEv) is the baseline. (2) Noise perturbation via Jacobian-vector-product sketching (T=50 probes, scaled to coil noise) through one VarNet, as an aleatoric estimate. Utility is judged by Pearson correlation between mean uncertainty and MAE inside each pathology box, plus a “danger zone” analysis (high error, low uncertainty); no decision rule is applied.
Data & evaluation: Trained on only 46 fastMRI+ “Mass” studies (40/4/2) to induce suboptimal reconstructions; tested on 182 studies (about 4k slices) with 1,198 annotated boxes across 7 pathology types, R in {4, 8}. Study-level BCa bootstrap CIs, one-sided Wilcoxon with BH-FDR for ME vs JVP.
Key results: - Image-level MAE 0.019 (R=4), 0.025 (R=8). ME box-level rho >= 0.70 for all 7 pathologies at R=4 (post-treatment change 0.90); weighted mean rho 0.80 (R=4), 0.83 (R=8) vs JVP 0.11 / 0.20; MEv 0.79 / 0.83 (no significant ME vs MEv difference, q > 0.1). - ME significantly > JVP for craniotomy (q < 0.001), WML and enlarged ventricles (q < 0.01). - JVP negative for some types (e.g. WML rho -0.24, posterior changes -0.11). - Danger-zone fraction at R=4: JVP 0-8.5% vs ME mostly < 1.1% (random expectation 6.25%). - Slice-level rho: ME 0.66, JVP -0.39 at R=4.
Strengths: - First pathology-stratified evaluation of reconstruction uncertainty with expert boxes, study-level bootstrap and confound analyses (box area, contrast, intensity). - Useful “danger zone” framing of confident misreconstructions. - Honest comparison showing aleatoric noise variance is a poor error indicator.
Limitations / open questions: - The proposed pathology-aware training adds nothing measurable over a vanilla seed ensemble (ME ~ MEv), so the “novel” contribution is not supported; ensemble models also share training data/architecture. - Correlation with MAE is confounded by ROI intensity (average delta-rho 0.25 for ME, 0.49 for JVP) and with a tiny training set (46 studies), single anatomy (brain), single acceleration pattern (equispaced), and per-box Pearson correlation says nothing about detecting failures (no AUROC/thresholded detection or clinician study). - Comparison is one-sided (JVP only, no MC dropout, posterior sampling or learned per-pixel variance), and the “reconstruction errors do not occur at low SNR regions” interpretation is speculative.
020 · Beyond Morphological Dilation: Revisiting Conformal Prediction for 3D Tumor Segmentation
Authors (first/last): Luisa Vargas / Maria A. Zuluaga (with Simone Rossi) · Affiliation: EURECOM, Biot, France
Task / clinical problem: Giving conformal guarantees for 3D brain-tumor segmentation that actually cover boundary errors and missed disconnected foci, relevant to surgical and radiotherapy margins.
Category tags: Conformal prediction & risk control; Segmentation uncertainty & failure detection. Modality: multi-parametric MRI (BraTS 2021); whole tumor / tumor core / enhancing tumor segmentation.
Method: Split conformal prediction on a fixed transformer segmenter, calibrating a nested family of expanded masks with the non-conformity score “smallest expansion that contains a fraction tau of the tumor”. Morphological dilation saturates (score capped at r_max=20) when a whole focus is missed, so formal coverage holds but the set is operationally vacuous. Instance-level CP splits matched vs. unmatched GT components, calibrating a spatial dilation score and a structural score (missed-volume fraction) each at alpha/2 with a union bound. Geodesic CP replaces dilation with Eikonal (fast-marching) arrival time using softmax-derived speed F = p + 0.05, so unreachable foci still get finite scores; the unified method uses geodesic scores on matched components plus the structural bound.
Data & evaluation: BraTS 2021 training set, 1,239 usable cases; 100 random 80/20 splits (991 calibration/248 test), alpha=0.1, tau=1 and 0.95. Metrics: formal vs. operational coverage, set volume in voxels, % vacuous splits. Baselines: morphological-dilation CP and threshold-based CP.
Key results: Dilation at tau=1 is vacuous in 100% of WT splits (operational coverage 0.842, 15.7% of cases capped) and 43% of ET splits. Unified: WT joint coverage 0.911 (497-524 voxel sets vs. thresholding ~8,910 voxels), ET volume 106 vs. 192 voxels for dilation (-45%), TC 125 vs. 205. Instance-only still vacuous on WT (0.853). At tau=0.95 geodesic gives the smallest sets (e.g., WT 118 vs. 135 dilation).
Strengths: - Clear, useful distinction between formal and operational coverage; shows a concrete failure mode of existing CP segmentation. - Preserves split-conformal validity while giving interpretable two-part certificate (matched coverage plus missed-volume bound). - Careful protocol: 100 splits, sensitivity to matching threshold kappa, code released.
Limitations / open questions: - Single dataset and one fixed segmenter; no check across models, centers or distribution shift (exchangeability assumed). - The certificate is not full containment; missed volume is bounded only as a fraction, and unmatched foci have no location, which limits clinical usability. Components <100 voxels were removed, and Bonferroni split is conservative. - Geodesic speed depends on softmax calibration and the floor epsilon; WT valid sets are larger than the (invalid) dilation, and no clinical margin or downstream-utility evaluation is given.
023 · Example-based Explainable Selective Classification with Graph Neural Networks for Urinary Sediment Examination
Authors (first/last): Keita Sasaki / Takao Onoye · Affiliation: The University of Osaka (Graduate School of Information Science and Technology; University of Osaka Hospital), Chiba University, Japan
Task / clinical problem: Classifying urinary sediment particles in microscopy and deferring uncertain ones to technicians, with visual reference examples justifying accept/reject decisions.
Category tags: Selective prediction & triage; Explainability. Modality: light microscopy (urine sediment); 7-class particle classification.
Method: A ResNet18 encoder is trained with cross-entropy, triplet loss and a proposed “same-mistake loss” that pulls together samples sharing a true label and the same wrong predicted class. For each input, K nearest training embeddings are retrieved and a 2-hop local graph is built; a graph attention network classifies the input node. GNNExplainer yields importance weights for the top-M neighbours, and the selection score is the importance-weighted embedding distance; inputs above a threshold tau (set for 95% coverage) are rejected, and the influential neighbours are shown as evidence.
Data & evaluation: Public Urine Sediment Dataset (5,376 images; 4,256/852/268 split; cropped particles in 7 classes: cast, cryst, epith, epithn, eryth, leuko, mycete). Metrics: accuracy, macro F1/precision/recall, AURC, AUROC at 95% coverage. Baselines on the same ResNet18: softmax confidence, energy, Mahalanobis, k-NN distance; qualitative comparison with SHAP/LIME.
Key results: Ablation F1: CE 0.944, +triplet 0.959, +SML 0.966, kNN 0.966, GNN 0.972, full selective 0.989 (precision 0.994). At 95% coverage F1: softmax 0.981, energy 0.968, kNN-distance 0.958, Mahalanobis 0.877 vs. proposed 0.989. AUROC of the proposed method (0.947) is below softmax (0.979); AURC is tied at 0.998.
Strengths: - Explanation is aligned with technician workflow (compare to reference particles) and is used by the rejection rule itself, not post-hoc. - Same-mistake loss is a simple, targeted regularizer for recurrent confusions. - Qualitative cases show rejection of an overconfident 99.6% softmax error.
Limitations / open questions: - Tiny test set (268 images; minority classes with 35-84 particles), single dataset and no repeated runs or confidence intervals; gains of ~0.008 F1 over softmax are within plausible noise. - Baselines are “adapted and simplified” and the coverage threshold was tuned on the reported data; the AUROC deficit is explained away rather than analyzed. - No technician study to show that example-based explanations improve review accuracy or speed; no multi-site validation, and pipeline cost (kNN + GNN + GNNExplainer per sample) is not reported.
024 · Beyond Boundary Noise: Aggregated Aleatoric Uncertainty Fails to Capture Presence Ambiguity in 3D Lung Nodule Segmentation
Authors (first/last): Simon Baur / Jackie Ma (with Wojciech Samek) · Affiliation: Fraunhofer Heinrich-Hertz-Institut; TU Berlin; BIFOLD, Berlin, Germany
Task / clinical problem: Testing whether segmentation uncertainty flags cases where radiologists disagree on whether a lung nodule exists at all (“presence ambiguity”), not just on boundaries.
Category tags: Label noise, inter-rater variability & metrics; Segmentation uncertainty & failure detection. Modality: chest CT; 3D lung nodule segmentation (LIDC-IDRI, external LNDb).
Method: Voxel-wise aleatoric uncertainty (expected entropy of MC dropout or deep-ensemble samples) is averaged inside the union of annotator masks (or the predicted mask) to give a case score. This score is tested as a detector of case-level ambiguity, defined as annotators splitting on presence (0 < agreement < 1). The comparator is a supervised “ambiguity head” (attention pooling plus 3-layer MLP, BCE loss) trained on frozen bottleneck features of the segmenter; it is framed as a supervision-advantaged upper bound, not a new method. Further baselines are Probabilistic 3D-UNet and Annotator-Confusion 3D-UNet.
Data & evaluation: LIDC-IDRI (4 annotators; 70/15/15 split) and LNDb as untouched external cohort (3 annotators). Four backbones (UNet3D, ResUNet3D, Attn-3DUnet, SegFormer3D; Dice 0.78-0.84). Metrics: AUROC, AUPRC, F1 for ambiguity detection, plus Spearman correlation with ordinal disagreement tier.
Key results: On LIDC, entropy aggregation over the GT mask reaches at most 0.48 AUROC (near random), 0.58 with predicted-mask aggregation. Ambiguity head: 0.74 AUROC, 0.67 AUPRC, 0.63 F1; Ann-Conf-3DUnet 0.60 (GT mask) / 0.73 (pred mask) AUROC; Prob-3DUnet 0.51 / 0.64. On LNDb: head 0.67 AUROC vs. at most 0.54 entropy and 0.65 Ann-Conf. Spearman with severity: head 0.63 vs. 0.43 best baseline on LIDC; much smaller on LNDb (0.22 vs. 0.18). UMAP shows ambiguity clusters in frozen features.
Strengths: - Asks a clinically meaningful and under-studied question and gives a clear negative result about entropy maps giving false reassurance. - Covers four architectures, two uncertainty estimators, two aggregation regions, and an external cohort. - Feature-space analysis suggests where the signal is lost (output/entropy aggregation, not encoder).
Limitations / open questions: - Ambiguity labels come from only 3-4 readers per case, and absolute performance is modest (AUROC 0.74, F1 0.63; near ties with Ann-Conf under predicted-mask aggregation), with no standard deviations in main figures. - The head is trained with ambiguity labels, so the comparison with unsupervised entropy is not like for like; mean-entropy aggregation is one of many possible case scores (e.g., max or volume-based). - Single task (lung nodules) and organ; generalization to other lesions is untested, and no downstream triage or reader study shows clinical benefit.
025 · Evaluating and Calibrating Diffusion Model-derived Uncertainty for Quantitative MRI Mapping
Authors (first/last): Shishuai Wang / Dirk H.J. Poot (with Stefan Klein, Juan A. Hernandez-Tamames) · Affiliation: Erasmus MC, Rotterdam; TU Delft, Netherlands
Task / clinical problem: Assessing whether the sampling spread of a diffusion-based quantitative MRI (T1/T2) mapping model is a trustworthy reliability signal and valid prediction interval.
Category tags: Regression & reconstruction uncertainty; Calibration. Modality: MRI (quantitative T1/T2 brain mapping, BrainWeb simulations plus one in vivo scan).
Method: A data-consistent denoising diffusion model is run K=10 times per input; the mean is the parameter map and the voxel-wise standard deviation is the uncertainty. Uncertainty is evaluated for error-awareness (Spearman with absolute error), high-error detection (AUROC for top-10% error voxels), selective prediction (risk-coverage curves/AURC with random and oracle rankings) and Gaussian interval coverage. Post-hoc calibration uses a 50-bin quantile lookup table that corrects the mean as a function of predicted value, then a single scalar lambda (median |residual|/sigma divided by z_0.5) rescales sigma to match the central 50% interval; voxels with high uncertainty are excluded from retained-risk estimates.
Data & evaluation: 20 BrainWeb phantoms: 19 for training and calibration (separate realisations), one held-out phantom with 20 noise realisations for testing; one healthy-volunteer 3T scan for qualitative display only. Metrics: MAE/RMSE, Spearman, AUROC, AURC, coverage probability accuracy CPA50. No external UQ baselines (only random and oracle rankings).
Key results: Uncertainty-error Spearman 0.260 (T1) and 0.612 (T2); high-error AUROC 0.773 and 0.953; AURC 0.079 and 0.012. Raw CPA50 0.287 (T1) / 0.370 (T2); after bias correction 0.228 / 0.240 and MAE 0.110 to 0.089 s (T1), 0.030 to 0.023 s (T2); after scaling (lambda 1.75 / 1.84) CPA50 0.063 and 0.055. Under-coverage persists at high nominal levels and residuals stay heavy-tailed.
Strengths: - Systematic multi-view evaluation (ranking, selection, coverage) of a “free” uncertainty from diffusion sampling. - Honest reporting that ranking utility does not imply calibrated magnitude. - Simple post-hoc correction fixed on a separate calibration set and applied unchanged to test data.
Limitations / open questions: - Quantitative evaluation is on one held-out synthetic phantom whose anatomy-family was seen in training; in vivo is qualitative only, with no pathology or acquisition shift. - Calibration targets only the central 50% interval and the guarantee is empirical (no conformal coverage), so tails and higher levels remain under-covered; no comparison with ensembles/MC dropout, nor sensitivity to K. - Uncertainty is clinically unvalidated: unclear what thresholds would be acted on, and T1 correlation (0.26) is weak.
027 · Improving Calibration of Black-Box Radiology AI Using Test-Time Augmentation
Authors (first/last): Nathan Le, Magdalini Paschali (equal) / Camila Gonzalez (with Akshay S. Chaudhari) · Affiliation: Stanford University (Radiology; Biomedical Data Science); Medical University of Vienna
Task / clinical problem: Improving probability calibration of proprietary (input-output only) radiology AI for triage, with no access to weights or training data.
Category tags: Calibration; Ensembles & Bayesian methods (TTA as ensemble). Modality: 3D CT; pulmonary embolism (CTPA) and intracranial hemorrhage detection.
Method: Each CT volume is perturbed with a radiologist-reviewed library of 6 augmentation types (scaling, rotation, shearing, motion blur, noise, undersampling) at 3 severities (18 augmentations), and the frozen model’s output probabilities are aggregated. DualTTA learns one non-negative weight per augmentation (minimizing NLL on a validation set) and blends the aggregate with the unaugmented prediction via a learned coefficient omega that is reduced to preserve the baseline argmax, unless the aggregate is more confident by more than 0.10. Compared with equal, max, greedy-search (GPS), V-ATTA and AugTTA aggregation; only scalar weights are trained.
Data & evaluation: INSPECT CTPA (PE; 12,716/1,838/3,676 scans, 24% prevalence) and RSNA ICH (15,215/2,174/4,354, 41% prevalence); black boxes are MERLIN CT foundation-model encoders fine-tuned with 3 seeds. Metrics: ECE (10 bins), Brier, reliability diagrams, AUC. Non-black-box comparators: temperature scaling, MC dropout, deep ensembles.
Key results: DualTTA ECE 0.239 to 0.109 on PE (-54%) and 0.051 to 0.029 on ICH (-43%); Brier 0.231 to 0.185 (PE), 0.081 to 0.074 (ICH). Comparators on PE: temp. scaling 0.242, MC dropout 0.240, ensembles 0.224; on ICH temp. scaling 0.032, ensembles 0.031 (best Brier 0.069). Max weighting worsens ECE (0.336 PE, 0.229 ICH). AUC unchanged or slightly lower (PE AugTTA 0.635 vs 0.651).
Strengths: - Realistic black-box setting with a clinically vetted perturbation library and learned scalar weights (negligible training cost). - Compares against both TTA aggregation variants and internal-access calibration methods, with ablations on augmentation type/severity. - Reports three seeds with small variance.
Limitations / open questions: - PE baseline is weak (AUC about 0.65), so large ECE gains may largely repair a poor model; ICH gains (0.051 to 0.029) are small relative to std (0.011-0.025), and DualTTA is barely better than V-ATTA/temperature scaling there. - Needs a labeled validation set from the deployment site, 19 inferences per case, and is tested only with in-house fine-tuned models on one site’s data splits; no true proprietary system or scanner/domain shift evaluation despite the motivation. - Only ECE/Brier (binary, 10 bins) are used; no risk-controlled thresholds or decision-level impact, and the tau=0.10 gate is a fixed heuristic.
028 · Well-Calibrated but Unusable: Calibration Error Does Not Certify Zero-Shot Chest X-Ray VLMs
Authors (first/last): Tianyi Zhang / Zixuan Liu · Affiliation: University of Washington, Seattle, USA
Task / clinical problem: Benchmarking how well post-hoc calibration works for zero-shot chest X-ray CLIP-style VLMs used for multi-label triage, and whether low ECE implies a usable model.
Category tags: Calibration; Vision-language models. Modality: chest X-ray (CheXpert, CheXphoto, NIH ChestX-ray14); 5 co-occurring findings (atelectasis, cardiomegaly, consolidation, edema, pleural effusion).
Method: The uncertainty construct is the pair-softmax probability of positive vs. negative prompt per finding. The benchmark crosses 5 backbones x 5 findings x 5 calibration-set prevalences (1-20%) x 5 seeds, and compares temperature scaling, bias-containing heads (Platt, matrix scaling with ODIR, pairwise log-linear), isotonic/beta/histogram binning, CalibPrompt soft prompts and a transductive adaptation stress test (SCA-T/TIM). Calibration is scored with macro ECE (15-bin), debiased smooth ECE and AUROC, and a triage rule is made by freezing a per-finding threshold at 90% sensitivity on the calibration split and transferring it to NIH.
Data & evaluation: CheXpert calibration split N=1,003 and expert-labeled test N=500; external CheXphoto and NIH ChestX-ray14. Backbones: BiomedCLIP, CheXzero, MedCLIP, MedSigLIP, OpenCLIP (zero-shot macro AUROC 0.54-0.89). Baselines are the calibrator families themselves; bootstrap CIs and exact permutation test (1/120) for the prevalence trend.
Key results: Prevalence acts through the intercept: temperature is flat across prevalence but worse for rarer findings (rho = -0.78); bias heads reverse it and Platt ECE falls 0.19 to 0.08-0.12 as calibration prevalence goes from 1% to 20%. All bias-ful heads reach a floor of macro ECE 0.082-0.102 regardless of AUROC (near-random OpenCLIP 0.082 vs. MedSigLIP 0.102); in-distribution refit lowers it to 0.020-0.032, so it is a calibration-to-test gap. SCA-T yields 89/625 below-chance cells, one with ECE 0.029 at AUROC 0.443. Frozen 90%-sensitivity threshold gives sensitivity 0.91 on NIH but flags 68% of findings at PPV 0.16 (worklist 86%).
Strengths: - Controlled prevalence sweep with multi-label structure, exact permutation test and bootstrap CIs; honest about non-independence of the 25 points. - Concrete, memorable demonstration that ECE alone can pick a below-chance ranker, plus a failure taxonomy (base-rate collapse vs. active mis-ranking). - Links calibration to a triage operating-point cost.
Limitations / open questions: - Small calibration (1,003) and test (500) sets and only five findings, so the 0.08-0.10 “floor” is confounded with sample size and a Bernoulli noise level. - The most dramatic “unusable” cases come from a deliberately adversarial transductive stress test (SCA-T), which may not reflect real deployment practice; the title overstates relative to the post-hoc results. - No conformal/risk-controlled alternative, no clinician or workflow validation, and NIH label noise (NLP-derived) confounds the external-transfer numbers.
029 · Uncertain but Useful: Leveraging CNN Training Variability into Data Augmentation
Authors (first/last): Ines Gonzalez-Pepe / Tristan Glatard (with Vinuyan Sivakolunthu, Yohan Chatelain) · Affiliation: Concordia University, Montreal; Krembil Centre for Neuroinformatics, CAMH, Toronto
Task / clinical problem: Quantifying training-time numerical/seed uncertainty of the FastSurfer brain segmentation CNN and reusing that variability as augmentation for brain-age regression from ROI volumes.
Category tags: Ensembles & Bayesian methods; Segmentation uncertainty & failure detection. Modality: T1 MRI; whole-brain (DKT atlas) segmentation and downstream brain-age regression.
Method: Training-time variability is induced with Monte Carlo Arithmetic (1-ulp stochastic rounding via Fuzzy PyTorch, 10 CPU runs) and with random seeds (15 GPU runs, data order fixed). Per-ROI uncertainty is the minimum pairwise Dice across repetitions and is compared to FreeSurfer 7.3.2 under MCA. Segmentations from the 15 seed models give 15 ROI-volume vectors per subject, used as “numerical ensemble” augmentation for RF/SVM/GB brain-age regressors, compared against a Gaussian copula synthetic generator and their combination.
Data & evaluation: FastSurfer retrained on its original datasets (HCP, ABIDE I/II, ADNI, IXI, LA5C, MIRIAD, OASIS1/2, MICA; ~465 internal test subjects); CoRR (32 subjects) for variability; HBN (1,000 subjects, ages 5-22) as external brain-age test; subject-grouped splits. Metrics: min-Dice, Spearman between MCA and seed regional rankings, brain-age MAE.
Key results: All cortical regions were significantly more variable in FastSurfer than FreeSurfer (Bonferroni-corrected); subcortical: less variable in 3/33, more in 12/33. MCA and seed regional rankings correlate (Spearman 0.877). Brain-age MAE at 15 repetitions on internal data: numerical ensemble 7.62 (GB) / 8.54 (RF) / 9.30 (SVM) vs. Gaussian synthetic 9.21 / 9.52 / 9.50; on HBN synthetic and combined win (best 1.43 SVM, combined) vs. ensemble 1.53-1.73. Chance MAE 20.61 years (internal) and 3.15 (HBN).
Strengths: - First MCA-based quantification of numerical uncertainty during DL training of a neuroimaging model, with hardware-matched comparison to a classical pipeline. - Cheap seed-based proxy validated against MCA; careful subject-level splits to avoid leakage. - Honest reporting that ranking flips on HBN and that correlation with ensemble size is not performance.
Limitations / open questions: - Variability is measured as worst-case (minimum) pairwise Dice with 10 repetitions and 32 test-retest subjects, and MCA was run only at epoch 10 on CPU; the link to clinical impact is asserted rather than shown. - Augmentation here is multiple ROI-volume vectors per subject from a fixed model family; the gain over Gaussian copula is mixed (loses on HBN), no baseline of simply averaging the 15 segmentations, and 15x training cost is large for modest gain. - “Uncertainty” is not turned into a decision (no calibration, selection or per-subject reliability measure); brain-age MAE of 7.6-9.3 years internal is poor, limiting practical relevance.
031 · Does Inter-Rater Variability Matter? Preclinical MRI Tumor Segmentation and Downstream Analysis
Authors (first/last): Dayu Tian / Andre F. Martins (with Sixing Li) · Affiliation: Werner Siemens Imaging Center and Cluster of Excellence iFIT, University of Tubingen; DKTK/DKFZ partner site Tubingen, Germany
Task / clinical problem: Whether inter-rater disagreement in manual tumor segmentation of mouse MRI changes the tumor-volume-based treatment-response conclusions.
Category tags: Label noise, inter-rater variability & metrics. Modality: 7T T2-weighted RARE MRI (preclinical, subcutaneous 4T1 tumors in mice); tumor segmentation and longitudinal volume analysis.
Method: Three raters (two senior, one junior) independently segmented tumors; a binarized STAPLE consensus serves as reference. Disagreement is quantified with Dice, HD95, the contested rim (union minus intersection), ICC(2,1)/(2,k), Bland-Altman bias and mixed-effects models of tumor size vs. Dice/HD95/relative volume error and proportional bias (mouse ID random intercept, mouse-level cluster bootstrap). Downstream, each rater’s volumes feed the same mixed-effects treatment x time-point model with Tukey post hoc tests, and significance and effect direction are compared across raters. No predictive uncertainty model is involved; variability is the “uncertainty” itself.
Data & evaluation: 164 scans from 66 mice (3 treatment groups: Control, A, B; time points TP0-TP2). Metrics as above; no baseline methods (descriptive study).
Key results: Rater-to-STAPLE Dice 0.924-0.949 and HD95 0.49-0.61 mm; pairwise Dice 0.865-0.887 and HD95 0.81-0.88 mm. Dice rises with tumor volume (beta 0.005 per 100 mm3, all P<0.001) while HD95 is unrelated to size. Volume ICC(2,1) 0.97, ICC(2,k) 0.99; volume bias vs. STAPLE: Rater 2 -13.5 mm3, Rater 3 +29.3 mm3, Rater 1 -0.15 mm3, with significant proportional bias for Raters 1 and 3. Treatment comparisons stayed significant with unchanged direction for all raters (TP1 p-value stars shifted between ** and ***).
Strengths: - Directly asks the downstream-relevance question rather than stopping at Dice, with appropriate repeated-measures statistics. - Separates relative (Dice, volume %) from absolute (HD95) disagreement, explaining why small tumors look worse. - Rater-specific, size-dependent bias analysis (Bland-Altman) beyond ICC.
Limitations / open questions: - Only three raters and a single tumor model/lab; the “inter-rater variability does not matter” conclusion is for large treatment effects in this dataset and may not hold for subtle effects, other endpoints or radiotherapy-style targets (no power or effect-size sensitivity analysis). - STAPLE consensus is not ground truth, and differing experience levels are confounded with rater identity; no link to model training, uncertainty estimation or multi-rater learning, which the introduction motivates. - Minor reporting inconsistency: the text gives Rater 1’s proportional-bias beta as +4.32 whereas the figure caption gives -4.32; analysis code was partly written with an LLM assistant (disclosed).
033 · A Principled Approach to Unsupervised Anomaly Detection
Authors (first/last): James Myles / Yingzhen Li (with Matthew Baugh, Johanna P. Muller, Bernhard Kainz) · Affiliation: Imperial College London; FAU Erlangen-Nurnberg; Nanyang Technological University
Task / clinical problem: Unsupervised anomaly detection that also infers what corruption (pathology intensity, bias, geometry) explains each abnormal image, rather than only scoring it.
Category tags: OOD & anomaly detection; Explainability. Modality: brain MRI (CamCAN train; BraTS T1/T2 and ATLAS stroke test), plus MorphoMNIST and MVTec AD for method development.
Method: UAD is posed as a Bayesian inverse problem: a healthy sample h is mapped by a parametrised corruption y = f(h, x), and the model infers the posterior over x. The anomaly score is the minimised joint energy, a sum of a healthy-likelihood term, a log-Jacobian volume term and a corruption-prior term. PaDiM (Mahalanobis, additive Gaussian) and CFLOW-AD (flow likelihood as epsilon tends to 0) are derived as special cases. Corruption parameters are inferred with a CNN posterior estimator (outperforming gradient descent on the energy); for MRI a restoration network and a texture/shape/bias-insertion corruption are used with a heuristic anomaly map from posterior samples.
Data & evaluation: MorphoMNIST Local (swollen/fractured digits), MVTec AD (image-level AUROC, 10 seeds, Wilcoxon with Holm correction), brain MRI benchmark (CamCAN 653 healthy; ATLAS 655; BraTS 369 subjects; AP and best Dice). Baselines: CNN regression, gradient descent, PaDiM, and published brain-MRI UAD methods (e.g., DISYREv2).
Key results: MorphoMNIST: posterior estimator AUROC 100.0 and centre error 0.87 px vs. regression 99.0/1.90 and gradient descent 82.0/5.18; dropping the healthy energy cuts fracture AUROC from 92.3 to 61.0. MVTec objects: PaDiM 92.9 to 95.2 AUROC with affine corruption + Laplace prior (+2.3); textures 98.8 vs. 99.0. Brain MRI: 38.0 Dice on ATLAS (second to DISYREv2 at 45.0); inferred lesion size Spearman 0.735 (BraTS-T2), 0.558 (T1), 0.600 (ATLAS); centre localisation 71.7%/54.3%/29.4%.
Strengths: - Unifies several UAD methods under one probabilistic energy, making the modelling assumptions explicit and giving a recipe for new variants. - Posterior over corruption parameters gives interpretable outputs (severity, geometry, bias) and a “de-corrupted” restoration. - Controlled ablations show each energy term’s role (healthy term catches out-of-scope anomalies).
Limitations / open questions: - Posterior estimators are trained on synthetic corruptions; for MRI the score is a heuristic, not the minimised energy, so the theory is only partly used on the clinical benchmark, and brain MRI results come from a single seed. - Medical detection numbers are “competitive”, not best (below DISYREv2 on Dice), and parameter recovery is moderate (bias correlation 0.12-0.49, localisation 29% on ATLAS); no calibration of the posterior and no assessment of whether inferred parameters are clinically meaningful. - Sensitivity to prior and corruption-family choice is unexplored, and the “principled” framing leans on hand-designed corruptions whose realism cannot be validated without labels.
035 · Counterfactual Marginalisation: Framework for Evaluating Robustness to Nuisance Variables
Authors (first/last): Yasin Ibrahim / Konstantinos Kamnitsas (with Hermione Warr, Robin J. Evans) · Affiliation: Department of Engineering Science and Department of Statistics, University of Oxford, UK
Task / clinical problem: Evaluating whether a chest X-ray classifier (pleural effusion) depends on demographic nuisance variables such as sex and age, including when disease labels are unavailable.
Category tags: Fairness & robustness auditing; Calibration. Modality: chest X-ray (CheXpert, MIMIC-CXR); binary pleural effusion classification.
Method: A structural-causal-model counterfactual image generator is used at test time: for each image, noise is abducted and sex/age are intervened on (16 counterfactuals: 2 sexes x 8 ages from 20-90), and the classifier’s predictions are averaged under a uniform intervention distribution. The resulting “intervention-aware” quantities define counterfactual marginal risk, interventional expected risk, CVaR/worst-case tail risk, counterfactual Brier/ECE, prediction variance, decision flip rate, observed-vs-marginalised disagreement and Spearman rank stability. It is analogous to TTA/ensembling but with causal interventions; a Rao-Blackwell argument shows lower-variance subgroup estimates than observational subgroup means when the SCM is correct.
Data & evaluation: Balanced test sets (equal sex, prevalence matched across sex and 3 age groups): CheXpert 5,180 and MIMIC-CXR 28,189 studies; three train/test settings (CheXpert-CheXpert, MIMIC-MIMIC, CheXpert-MIMIC natural). Predictors: a baseline, logit offsets for females (+0.5/1/2), and models trained with induced sex bias or age bias (drop probabilities 0.8-0.95), 3 seeds. Baselines: standard cross-entropy on original images, original ECE and stratified AUC gap.
Key results: Correct Transition Count (out of 9 bias increases where risk should increase): original risk 6.33 vs. R_CM 8.33, R_IE 8.66, CVaR(0.5) 8.33, worst-case 7.33. CheXpert: R_orig stays ~0.44-0.45 across logit offsets 0 to +1 while R_CM rises 0.501 to 0.629 and R_IE 0.594 to 0.771. Stability metrics track bias (flip rate 0.143 to 0.243, rank stability 0.920 to 0.847 for logit +2) and correlate strongly with the AUC gap (Fig. 3, no coefficient given in text).
Strengths: - Reuses SCM counterfactual generators as an evaluation tool, offering label-free bias indicators and tail-risk measures. - Controlled bias-injection protocol with known ground-truth ordering of predictor bias gives an interpretable validation criterion. - Candid caveat that results depend on the realism and validity of the generator.
Limitations / open questions: - Validated only on synthetically induced biases, with one task, one counterfactual generator and trained on CheXpert; sex/age counterfactual images may not be faithful, and the metrics partly measure generator behaviour (reported results for settings 2 and 3 omitted for space). - Evaluation is nearly circular: the “bias” is detectable by counterfactual metrics because the injected offsets act on sex-correlated features; no real-world biased model, no correlation values or CIs, and no comparison against other fairness/robustness audits beyond R_orig and stratified AUC. - The variance-reduction proposition requires correct SCM specification and sigma_gen small; sensitivity to causal graph, intervention distribution and generator uncertainty is deferred to future work. Paper structure is unfinished (“Title Suppressed Due to Excessive Length”).
036 · Foundation Model and Radiomics Distance Scores for Post-Hoc Segmentation Failure Detection
Authors (first/last): Simon Johannes Joham / Martin Urschler · Affiliation: Medical University of Graz; Graz University of Technology; BioTechMed-Graz (Austria)
Task / clinical problem: Flag likely-failed predictions of an already-deployed segmentation model (black box, only image + predicted mask visible) so experts can triage them under protocol and population shift.
Category tags: Segmentation uncertainty & failure detection; OOD & anomaly detection. Modality: MRI; prostate and hippocampus segmentation.
Method: Two failure scores, each a Mahalanobis distance (Ledoit-Wolf covariance) to a reference set of ground-truth-mask cases from the training site. Rad-MD-Mask uses pruned 3D radiomic shape features of the predicted mask (6 of 14 prostate, 11 hippocampus). The FM score overlays the mask on the slice, encodes with frozen DINOv3, pools patch tokens weighted by mask coverage, L2-normalises (Mahalanobis++) and aggregates slices by mask area. A higher distance means higher failure risk, used to rank/defer cases (selective prediction). RadDINO and 3DINO are ablated.
Data & evaluation: Prostate multi-site (RUNMC reference; BMC, I2CVB, UCL, BIDMC, HK; n=86 test) and hippocampus (Decathlon reference; Dryad, HarP; n=320). 5-fold nnU-Net ensemble, majority vote. Metric: E-AURC (x10^-2, lower better) with 1-Dice risk, reported both pooled and within-site, site-stratified bootstrap. Baselines: ensemble pairwise Dice (Ens-mpd), Atlas-RCA, Rad-L2, Rad-MD-Img.
Key results: Mean within-site E-AURC across both tasks: Atlas-RCA 2.05, Ens-mpd 2.60, DINOv3-MD-OvW 2.60, Rad-MD-Mask 2.70; all paired differences vs Atlas-RCA have CIs spanning zero. Whole-image CLS embeddings are poor (within-site prostate 7.3), mask-weighted + overlay cuts it to 3.0. Pooled evaluation rewards site ordering: Rad-L2 gets 5.5 pooled vs 7.5 within-site on prostate. Backbone choice (DINOv3/RadDINO/3DINO) matters little.
Strengths: - Genuinely post-hoc: needs only reference mean/covariance, no registration, ensemble or model internals. - Evaluation insight (pooled vs within-site E-AURC) is a useful, transferable methodological point. - Clear ablation showing mask conditioning, not backbone, drives performance.
Limitations / open questions: - Few sites and tiny per-site n (12-30 prostate cases) give wide CIs; only two binary organ tasks, one reference site, one nnU-Net model. - Reference set is the model’s own training data; sensitivity to a deployment-site reference is untested, and shape scores may not transfer to lesions or multi-class targets. - Score is a ranking signal with no calibrated threshold or coverage/risk guarantee; neither proposed score beats the strongest baselines within-site.
038 · Beyond Uncertainty: Generalizable Failure Monitoring for Surgical Segmentation under Acquisition Degradation
Authors (first/last): Hieu D. Pham / Thanh Trung Huynh · Affiliation: College of Engineering and Computer Science, VinUniversity, Hanoi, Vietnam
Task / clinical problem: Detect silent, confident failures of a frozen instrument segmenter in endoscopic surgical video under smoke, blur, noise and similar acquisition degradation.
Category tags: Segmentation uncertainty & failure detection; Conformal prediction & risk control. Modality: endoscopic/robotic surgical video; instrument segmentation (EndoVis 2017).
Method: TCSR-Monitor wraps a frozen ResNet34-U-Net and extracts 22 cheap scalar features (confidence, mask shape, temporal IoU, image quality) per frame, feeding an XGBoost failure-risk classifier (failure = IoU < 0.5 or 0.75). An alarm fires when risk exceeds a threshold chosen by split-conformal miss-rate control (alpha = 0.10), globally or Mondrian per severity group. Validation protocols: leave-one-corruption-out (LOCO), a circularity control (corrupted frames only) and SAM2 zero-shot transfer.
Data & evaluation: EndoVis 2017, sequences 1-7 train/calibration, 8-10 test (825 frames); six synthetic corruptions x five severities (24,750 test frames). Baselines: max-softmax, entropy, temporal heuristic, learned confidence-only monitor. Metrics: AUROC, AUPRC, miss-rate, false-alarm rate, sequence-level bootstrap.
Key results: Clean test AUROC 0.877 vs entropy 0.764 (IoU<0.5; 1.7% prevalence); but sequence-bootstrap CI is [0.48, 0.99]. LOCO AUROC 0.814 vs entropy 0.481, upper bound 0.827. Within corrupted frames AUROC 0.946 vs 0.594. Global threshold false-alarms on 40.4% of correct frames at severity 3; Mondrian fixes miss-rate (severity 1: 50.5% to 9.3%) but raises corrupted false alarms from 17.6% to 34.2%. On SAM2, entropy wins (0.984 vs 0.896).
Strengths: - Unusually honest evaluation design (LOCO, circularity control, sequence-level bootstrap, reported negative SAM2 result). - Cheap (<0.5 ms/frame), model-agnostic features, with conformal calibration separated from scoring. - Surfaces the false-alarm cost of miss-rate control explicitly.
Limitations / open questions: - Only EndoVis 2017 with 3 test sequences and synthetic corruptions; the external CholecSeg8k check failed from a preprocessing bug, so no real-shift validation. - Conformal guarantee is on failed frames with a learned score; calibration data come from the same corruption distribution, and video frames are not exchangeable. - Alarm burden is too high for clinical use and “beyond uncertainty” fails for SAM2; confidence still carries 58% of feature importance.
040 · SegWithU: Deterministic Perturbation Probes for Single-Backbone-Pass Risk-Aware Medical Image Segmentation
Authors (first/last): Tianhao Fu / Yucheng Chen · Affiliation: University of Toronto; McGill; University of Waterloo; Vector Institute; Project Neura (Canada)
Task / clinical problem: Cheap voxel-wise uncertainty maps for 3D segmentation that support both probability calibration and error ranking/selective review, without repeated inference.
Category tags: Segmentation uncertainty & failure detection; Calibration. Modality: cardiac MRI (ACDC), brain MRI (BraTS2024), abdominal CT (LiTS); multi-class 3D segmentation.
Method: A small supervised head (~0.1M params) is attached to decoder features of a frozen DynUNet. It learns a compact probe space and applies 8 fixed cosine-sign perturbation patterns to logits, giving variance across perturbed softmaxes (epistemic-like), probe energy and residual terms. These combine with margin and entropy into two maps: a positive calibration map that tempers logits (hard masks unchanged) and an unconstrained ranking map for error localisation. Training uses NLL plus ranking losses (error-correlation BCE, pairwise margin, tail penalty). Voxels are rejected by ranking-map value for selective prediction.
Data & evaluation: ACDC, BraTS2024 (200 train/100 test sampled from public train), LiTS (last 10 cases as test); 5-fold + all-data DynUNets (Dice 90.4/62.8/78.2). Baselines: Deep Ensembles, TTA, MC Dropout, temperature scaling, DUQ, DDU-Seg, DUE, ConfidNet. Voxel-level AUROC, AURC (x10^-4), Brier, Wilcoxon with Holm correction.
Key results: AUROC/AURC 0.9838/2.4885 (ACDC), 0.9946/0.2660 (BraTS), 0.9925/0.8193 (LiTS), best of all methods incl. 5-model ensembles on ACDC (2.5326). Wall-clock 0.23 s vs 1.72 s ensemble on ACDC. Ablation: ranking-only AURC 2.99 vs calibration-only 28.05; removing the pairwise loss gives AURC 16.75.
Strengths: - Clean separation of calibration vs ranking roles, with ablations showing why. - Preserves the frozen backbone’s masks and is far cheaper than ensembles/TTA/MCD. - Broad baselines and paired significance testing.
Limitations / open questions: - Voxel-level AUROC/AURC is dominated by easy background voxels (very small AURC); no case-level failure detection or Dice-vs-coverage analysis. - Supervised head needs labelled held-out data; random splits (not site/scanner-held-out) and no OOD shift test; LiTS n=10 is underpowered; BraTS Dice only ~0.63. - “Perturbation instability” interpretation is heuristic; ranking map is a handcrafted blend and not a probabilistic uncertainty with guarantees.
041 · Layer Selection in VLMs for Zero-Shot OOD Detection via Multi-Resolution Entropy Estimation
Authors (first/last): Shyam Nandan Rai / Christian Ledig · Affiliation: xAILab Bamberg, University of Bamberg, Germany
Task / clinical problem: Zero-shot detection of out-of-distribution medical images with CLIP-style medical VLMs, without training on OOD data.
Category tags: OOD & anomaly detection; Vision-language models. Modality: histopathology (MIDOG) and brain MRI (OASIS) vs CT/other far-OOD.
Method: Scores each input by Maximum Concept Matching (max softmax of image-text cosine similarity over ID prompts), computed per encoder layer after projecting intermediate tokens with the final projection head. Candidate layer subsets (always including the last layer, at most 4 layers) are averaged, and the subset whose ID-score distribution has minimum entropy is chosen. The novelty is averaging histogram entropy over bin counts {4, 8, 16, 32, 64} instead of one bin count. Threshold on the averaged MCM score flags OOD.
Data & evaluation: OpenMIBOOD-derived benchmarks: MIDOG ID with near-OOD (other cancer types/species/scanners) and far-OOD (CCAgT, FNAC cytology); OASIS3-MRI ID with OASIS3-CT near-OOD and MSD-H/CHAOS far-OOD. BioMedCLIP and UniMedCLIP (ViT-B/16). Baselines: MCM, Ju et al. (hierarchical prompts), De la Jara et al. (single-bin entropy). AUROC and FPR95.
Key results: UniMedCLIP OASIS: near-OOD AUROC 100/FPR95 0.0 (MCM 55.2/99.9), far-OOD 99.2/1.0. MIDOG UniMedCLIP far-OOD 97.4/13.4 but near-OOD only 54.6/94.4. BioMedCLIP MIDOG near-OOD is worse than MCM (36.4 vs 52.7). Single-bin entropy selection varies up to 19.3% AUROC with bin count.
Strengths: - Useful finding that the best layer is modality-dependent and not the last one. - Simple, training-free, ID-only layer selection method. - Explicit analysis of the bin-size instability of entropy-based selection.
Limitations / open questions: - Only two datasets/modalities and two backbones; results are mixed on BioMedCLIP and near-OOD MIDOG stays near chance, so “consistently outperforms” is overstated. - Heavy dependence on hand-written LLM-generated prompts (4 and 9) and the choice of bin set, subset size cap and uniform averaging; no seeds/variance reported. - Whether the ID-entropy criterion actually tracks OOD performance is not shown; no clinical shift scenarios (site/scanner within same modality) beyond benchmark splits.
042 · Uncertainty Identifies Difficult Samples Across Methods: A Multi-Task Study on a Heterogeneous Skin Lesion Dataset
Authors (first/last): Leon Koole / Matias Valdenegro-Toro · Affiliation: Bernoulli Institute, University of Groningen, Netherlands
Task / clinical problem: Do different uncertainty methods agree on which skin-lesion images are hard, and is the ranking good enough for referral to a clinician?
Category tags: Ensembles & Bayesian methods; Selective prediction & triage. Modality: dermoscopy/clinical/TBP photographs (ISIC Archive); malignant vs benign and 5-class diagnosis.
Method: Shared ImageNet EfficientNet-B3 with two heads (binary H1, five-class H2) and five UQ methods plus a softmax baseline: MC Dropout, DropConnect, Flipout, Deep Ensembles (5 members), DUQ. Uncertainty is predictive entropy of the mean prediction, split into epistemic (mutual information) and aleatoric parts. Cases are deferred by descending entropy (risk-coverage). “Difficulty” is a leave-one-model-out consensus tier (number of other methods that err) and a held-out indeterminate-diagnosis set.
Data & evaluation: 92,092 ISIC images from 18 sources; 5,920 test images (70/30 benign/malignant), 3,289 indeterminate cases held out. Metrics: accuracy, ECE, confidence AUROC, AURC, Spearman entropy correlation, regression of entropy on metadata.
Key results: Deep Ensembles best calibrated (ECE 0.013 H1, 0.019 H2; AURC 0.012 on H1), deferring 20% most uncertain drops H1 error from 7.4% to 2.5%. Flipout failed (acc 0.868/0.763). Inter-method per-sample entropy Spearman 0.54-0.91. Entropy dips and overconfidence peaks on tier-4 cases, so confidently wrong cases are missed. Test set has about zero malignant Fitzpatrick VI cases.
Strengths: - Frames UQ as sample difficulty and includes a model-independent check (indeterminate set). - Honest identification of the “confidently wrong” blind spot and the skin-tone gap, plus shortcut cues (white background, ruler marker). - Multi-source pooled data and metadata regression.
Limitations / open questions: - Single backbone/run, five stochastic passes only, no seeds or CIs; Flipout’s failure looks like a training issue rather than method property. - No OOD evaluation and no clinician review; difficulty tiers are circular since all models share backbone/data (correlations up to 0.91 confirm this). - Fairness conclusions cannot be drawn with ~0-6 malignant samples for darker types; ECE binned estimates and no recalibration baselines.
046 · Confidence-Tiered Quality Control for Reliable Radiomic Biomarkers in Multicentre PET-CT
Authors (first/last): Marta V. Araujo / Suzanne S. Gisbertz · Affiliation: Amsterdam UMC, University of Amsterdam (Netherlands)
Task / clinical problem: Per-scan reliability assessment of SUV quantification and PET-CT alignment in multicentre FDG PET-CT before radiomic prediction of pathological complete response in oesophageal cancer.
Category tags: Fairness & robustness auditing; Selective prediction & triage. Modality: FDG PET-CT; oesophageal cancer, radiomics QC.
Method: A deterministic, rule-based pipeline assigns PASS/WARN/FAIL tiers on two axes. SUV axis: vendor-aware, confidence-ranked resolution of the scan reference time from DICOM tags (HIGH to VERY LOW), plus liver SUVmean window [1.5, 2.5]. Spatial axis: body-mask Dice, centroid offset and edge-contact between PET and CT. The tiers are explicitly not calibrated probabilities. Downstream, features are re-evaluated on PASS+WARN and PASS-only subsets with matched-random subset controls.
Data & evaluation: 130 patients from four Dutch centres (PRIDE study; 26 pCR of 124 with endpoint). SUV validated vs ACCURATE research interface (127 paired scans). PyRadiomics feature stability (ICC(2,1) under VOI perturbation), nested-CV ridge for pCR (AUC, Brier, calibration slope), threshold-sensitivity sweeps.
Key results: 78 PASS / 41 WARN / 11 FAIL (40% flagged); all FAIL on spatial axis, 40/41 WARN on liver SUV. SUV agreement ICC 0.78 (CI 0.47-0.94), median difference 1.3%. pCR AUC 0.52 (all) to 0.61 to 0.66 (PASS-only), but matched-random controls place PASS-only at the 90th percentile (P=0.10); stable PET features 82 vs random mean 78.5. Raising liver upper bound 2.0 to 6.0 moves PASS from 15 to 118 scans.
Strengths: - Transparent, auditable per-scan tiers with traceability to DICOM evidence. - Commendable self-critique: matched-random controls and threshold sweeps expose confounding by centre/vendor. - Honest separation of pipeline contribution from downstream claims.
Limitations / open questions: - Thresholds come from guidelines, not expert-adjudicated labels, so flags are unvalidated; liver window is stricter than EANM and effectively one-sided (SUV > 2.5) and drives most tiers. - Small cohort (PASS-only n=74, 14 events); downstream benefit not separable from centre composition; ICC CI wide. - Little connection to uncertainty quantification proper (no calibration, coverage or risk guarantee); no noise/resolution checks.
053 · Quantile regression enables reliable, uncertainty-aware endoscopic scoring in ulcerative colitis clinical trials
Authors (first/last): Sara Sangalli / Krishna Chaitanya (last authors equal: Kristopher Standish, Pablo F. Damasceno, Krishna Chaitanya) · Affiliation: Johnson & Johnson (USA)
Task / clinical problem: Defer uncertain AI endoscopy-video severity scores (continuous Mayo Endoscopic Subscore, 0-3) to experts without losing treatment-effect sensitivity in ulcerative colitis trials.
Category tags: Regression & reconstruction uncertainty; Selective prediction & triage. Modality: endoscopy video; UC severity regression (CMES).
Method: Same ARGES backbone (DINOv2 ViT-B, temporal transformer, attention MIL) with a quantile-regression head: 5% and 95% quantiles via pinball loss plus a mean output trained with MSE. Interval width is the uncertainty score; videos above a validation-chosen threshold are deferred to human MES (selective regression, risk-coverage). Compared with MC Dropout, mean-variance, deep evidential regression, deep ensembles and a QR ensemble. Deferral policy evaluated by trial-level Hedges’ g.
Data & evaluation: 5,918 videos from four trials (VEGA, JAKUC, UNIFI, ASTRO), 60/20/20 split; tests on UNIFI (153) and ASTRO (587) hold-outs plus unseen QUASAR Ph2b (614) and ANTHEM-UC (809). Metrics: selective MSE, validation-to-test threshold transfer, interval coverage, Hedges’ g vs placebo (200 mg, 400 mg).
Key results: Full-coverage MSE (ANTHEM) 0.430 QR vs 0.486 ARGES; at 90% coverage 0.399 vs 0.466 (MCD). QR is lowest-variance (SD ~0.01 vs 0.02). 90-95% interval coverage. Hedges’ g (200 mg): MES 0.55, ARGES 0.734, QR 0.742, rising to 0.81 with 15% uncertainty-based deferral; random deferral falls to 0.661/0.607 at 15%/25%.
Strengths: - Links uncertainty to a trial-level decision metric (effect size, dose selection) rather than MSE alone. - Random-deferral control and validation-to-test threshold transfer on an unseen trial. - Single-pass model competitive with ensembles; multi-seed reporting.
Limitations / open questions: - Differences among methods are small (QR vs ensemble within noise on several trials); QR ensemble is often best, so “matches ensembles” is soft. - Deferral to experts is simulated retrospectively; interval has no formal conformal guarantee or distribution-shift check and relies on weak, noisy mean-of-two-reader labels (ANTHEM has one reader). - Hedges’ g gains from a single trial with two doses and no CIs on the deferral gains; aleatoric/epistemic not disentangled.
055 · Spatial Autoregressive Modeling of DINOv3 Embeddings for Unsupervised Anomaly Detection
Authors (first/last): Ertunc Erdil, Nico Schulthess (equal) / Ender Konukoglu · Affiliation: Biomedical Image Computing Group, ETH Zurich (Switzerland)
Task / clinical problem: Fast, memory-efficient unsupervised anomaly detection (lesion localisation) trained only on healthy slices.
Category tags: OOD & anomaly detection. Modality: brain MRI (BraTS2021), liver CT (BTCV+LiTS), retinal OCT (RESC) from BMAD; 2D slices.
Method: Patch embeddings from frozen DINOv3-S form a 2D grid. A masked (PixelCNN-style) CNN with dilation factor 4 models each patch conditionally on preceding patches in raster order, with a von Mises-Fisher likelihood (equivalent to cosine loss). The per-patch negative log-likelihood is the anomaly score, upsampled to a pixel map in one forward pass; no memory bank or nearest-neighbour search.
Data & evaluation: BMAD: BraTS2021 (8,179 normal/3,119 anomalous), BTCV+LiTS (2,468/733), RESC (5,383/834); VisA in supplement. Pixel AUROC/AUPR (3 seeds), runtime and memory on RESC. Baselines: DRAEM, UTRAD, RD4AD, STFPM, PaDiM, PatchCore, CFA, CFLOW, AnomalyDINO, DINO-DPMM, Dinomaly (v2-S and v3-S).
Key results: BraTS AUROC 98.44, AUPR 73.88 (dilated), best vs AnomalyDINO v3-S 69.49. RESC AUROC 97.29 (standard conv), runtime 14 ms and 0.2 GB vs AnomalyDINO 585 ms/11.3 GB and Dinomaly v3-S 17 ms/0.3 GB. Liver CT AUPR only 8.64 vs Dinomaly 25.33 (4th). Image-space AR AUPR 11.03 on BraTS vs 57.91 in embedding space. DINOv3-7B changes AUPR 73.88 to 74.56.
Strengths: - Simple, lightweight parametric normality model with a real speed/memory advantage. - Informative ablations (causal vs bidirectional, dilation, image-space AR, backbone size). - Candid about the BMAD slice-labelling bias.
Limitations / open questions: - Not best on liver CT or RESC AUPR; benefit of dilation is dataset-dependent and config selection has no principled rule (and was tuned on test-like data). - Slice-based BMAD protocol (normal slices from tumour patients, brain-centre bias) inflates results and gives no patient-level or 3D evaluation. - Anomaly score is an uncalibrated likelihood with no threshold, detection-level metric or uncertainty evaluation; pixel-space AR likelihood failures are cited but not tested against OOD benchmarks.
058 · When Voxels Are Not Equal: Spacing-Driven Metric Bias and Metric Uncertainty in Segmentation
Authors (first/last): Khadijah Mohammed / Irina Voiculescu · Affiliation: Department of Computer Science, University of Oxford (UK)
Task / clinical problem: How CT slice thickness biases segmentation evaluation (boundary metric, Dice aggregation) and how model boundary uncertainty varies with thickness.
Category tags: Label noise, inter-rater variability & metrics; Segmentation uncertainty & failure detection. Modality: CT (KiTS23); kidney, tumour and cyst segmentation.
Method: Compares Symmetric Boundary Dice with a 3x3x3 voxel neighbourhood (SBDcub) to a physical-space variant (SBDphys, r=1.5 mm, z-radius floor(r/tz)). Evaluates three Dice aggregation schemes (pooled, per-case mean, volume-weighted). Uses mean voxel-wise softmax entropy at ground-truth boundaries, especially the top/bottom axial slices, from a trained nnU-Net; tests relation to slice thickness (Kruskal-Wallis, Mann-Whitney, Spearman, bootstrapped regression) against a partial-volume prediction, and links per-case metric inflation to entropy.
Data & evaluation: KiTS23, slice thickness 0.5-5 mm; 74 held-out cases (fold 0) for Dice analysis, 283 cross-validated cases (57 thin, 34 medium, 192 thick) for SBD and entropy (280 with softmax). No external baselines.
Key results: Kidney SBDcub is 0.031 higher for thick than thin slices; SBDphys reverses this to -0.011 (robust for r = 1.0-2.5 mm). Dice aggregation: cyst 0.485 (pooled) vs 0.236 (per-case), tumour 0.548 vs 0.666. Z-boundary entropy rises with thickness (rho=0.233, p<0.001; slope 2.3e-3 bits/mm, CI [5.8e-4, 4.0e-3]); per-case Delta-SBD vs entropy rho=+0.083, p=0.166 (no association).
Strengths: - Concrete, easily reproducible demonstration that metric definitions in voxel units are spacing-dependent. - Highlights how aggregation conventions confound cross-paper Dice comparisons. - Pre-specified tests, bootstrap CIs and robustness over radii.
Limitations / open questions: - Thickness groups are imbalanced and confounded with scanner/site/protocol; nnU-Net trained on mixed thickness, one model, one dataset; entropy effects are small (rho 0.23). - Interpreting rising z-boundary entropy as “model knows annotation is imprecise” is unsupported: no inter-rater data and no calibration or comparison to a purpose-trained inter-rater method; the paper itself admits this. - SBDphys choice (floor and r=1.5 mm) is ad hoc, with no comparison to established Normalised Surface Dice; the physical-space tolerance becomes zero in z for thick slices, which is arguably overly strict.
059 · Predictive Entropy as a Joint Screen for Error and Paraphrase Instability in Medical Vision-Language Models
Authors (first/last): Binesh Sadanandan / Vahid Behzadan · Affiliation: SAIL Lab, University of New Haven, USA
Task / clinical problem: Binary presence questions (“is pleural effusion present?”) answered by medical VLMs on chest X-rays. Models are confidently wrong and also flip answers when the question is reworded; can one cheap score flag both?
Category tags: Vision-language models; Selective prediction & triage. Modality: CXR (MIMIC-CXR, PadChest); yes/no finding-presence VQA.
Method: MedGemma-4B-IT is reduced to a binary classifier by reading first-token Yes/No logits; predictive entropy of sigmoid(z+ - z-) is the uncertainty score (a monotone function of the absolute logit margin, which the authors acknowledge). A targeted LoRA (layers 15-19, trained on 2,000 MIMIC questions with a consistency-accuracy loss) is the main model. Entropy is tested as a predictor of paraphrase flips (any of ~5 PSF-Med rewrites changes the answer) and as a deferral score via an entropy-quantile threshold. Compared against temperature scaling, MC Dropout on the adapter (K=10, p=0.05), and a five-seed LoRA ensemble; replicated on LLaVA-RAD-7B.
Data & evaluation: MIMIC-CXR (ID, n=196 questions) and PadChest flip bank (OOD, n=861, ~4,251 rewrites). ECE, Brier, NLL, AURC, flip-prediction AUROC, Mann-Whitney, bootstrap CIs (B=2000).
Key results: Entropy predicts flips at AUROC 0.823 (PadChest) and 0.821 (MIMIC), 0.828 +/- 0.021 over five seeds, 0.83 on LLaVA-RAD; unchanged under operator-preserving (0.827) or ex-negation (0.826) flip definitions. At 80% coverage error falls 8.6% to 3.3% and flip rate 12.1% to 5.7%. At 5% risk target softmax answers 88.5% (MC-Drop 88.4%, ensemble 23.8%); error-detection AUROC 0.862 vs ensemble 0.751. Targeted LoRA cuts PadChest flip rate 74% to 13%, accuracy 91.4%; temperature scaling lowers ECE 11.1% to 3.6%.
Strengths: - Honest framing: the entropy-margin link is analytic and the paper measures its strength rather than claiming novelty. - Flip-definition invariance, seeds, and a second architecture strengthen robustness; AUROC is read alongside prevalence (flags the near-constant-classifier trap). - Practical, cheap deployment message with a held-out threshold transfer check.
Limitations / open questions: - Tiny evaluation sets (196 ID), ID questions share images with training, single MIMIC-to-PadChest shift, only binary presence VQA; free-text generation untested. - Multi-pass baselines are deliberately weak (adapter-only dropout at 0.05 gives ~0 mutual information; uniform seed ensemble with some seeds at 52% accuracy), so “one pass suffices” is not a general verdict. - Paraphrases are LLM-generated with only 28 of 861 items individually clinician-reviewed; abstention workflow and coverage-vs-error guarantees are empirical with no formal risk control.
062 · FetalEDL: OOD-Aware Evidential Deep Learning for Reliable Fetal Ultrasound Plane Classification
Authors (first/last): Srivibha Parthasarathy / Mohanasankar Sivaprakasam · Affiliation: IIT Madras (EE Dept., HTIC, Sudha Gopalakrishnan Brain Centre), MediScan Systems, Chennai, India
Task / clinical problem: Classify 20 ISUOG standard second-trimester fetal planes from B-mode ultrasound while rejecting acquisition-mode OOD inputs (Colour/PW Doppler, non-fetal US) and deferring poor-quality images to sonographers.
Category tags: OOD & anomaly detection; Selective prediction & triage. Modality: ultrasound (obstetric B-mode); standard plane classification.
Method: ConvNeXt-Small with Softplus evidence head parameterising a Dirichlet (evidential deep learning), giving a single-pass decomposition into vacuity (lack of evidence) and dissonance (conflicting evidence). Training adds an OOD KL regulariser pushing OOD Dirichlets to uniform, feature-similarity-weighted sampling that oversamples near-OOD examples, and a vacuity regulariser penalising correct predictions with vacuity > 0.95. At inference, images with vacuity above a fixed threshold (tau = 0.99, chosen on validation) are abstained on.
Data & evaluation: Private B-mode dataset, 2,416 patients, 3 scanners; patient-wise split 1,078/357/981 patients (11,319 test images); OOD classes seen in training. Baselines: MSP, MC Dropout, plain EDL, each +/- temperature scaling; metrics accuracy, ECE, OOD AUROC/AUPRC, macro-F1, gross-error (inter-anatomy) rate.
Key results: FetalEDL+N+V (TS) OOD AUROC 0.991 / AUPRC 0.866 vs MSP 0.914 / 0.517 and MC-D 0.917 / 0.501; accuracy 96.9% (MSP/MC-D 97.2%). Abstaining on 2.16% of images raises accuracy 96.86% to 97.85% and gross-error rate 1.1% to 0.47% (58.1% of gross errors caught). Raw ECE rises (0.198) but TS restores it to 0.029. Abstained images judged poor quality by two clinicians.
Strengths: - Single-pass uncertainty with interpretable vacuity/dissonance split tied to clinically meaningful failure types. - Realistic OOD categories (Doppler, maternal US) from the same scanners; patient-level splits. - Honest reporting of ECE and accuracy costs, plus ablation of the near-OOD sampling and vacuity terms.
Limitations / open questions: - OOD categories seen in training, so this is closed-set OOD exposure, not generalisation to novel scanners/modes; single site, private data. - Large AUROC gains are mostly ID-vs-OOD separation; selective gain on hard ID images is small (+1 point accuracy) and tau chosen on a split with unclear tuning; no comparison with deep ensembles or other OOD-exposure methods (e.g. outlier exposure, energy). - Clinical review of abstained images was unblinded, qualitative, by two reviewers; low-support classes degrade (supplement).
064 · Explanation Uncertainty in the Classification of Pulmonary Nodules
Authors (first/last): Sandra Bedrossian / Matias Valdenegro-Toro · Affiliation: Bernoulli Institute, University of Groningen; UMC Groningen (Radiology); Beijing Tiantan Hospital
Task / clinical problem: Benign vs malignant lung nodule classification on CT with per-prediction uncertainty and saliency explanations that carry their own uncertainty maps.
Category tags: Explainability; Ensembles & Bayesian methods. Modality: CT (LIDC-IDRI nodule patches); nodule malignancy classification.
Method: An ensemble of ImageNet-pretrained ResNet50, DenseNet121 and ViT-B/16; predictive uncertainty is binary entropy of the mean malignancy probability, with the 90th-percentile entropy as an arbitrary “uncertain” cut-off for human review. Seven XAI methods (GradCAM, GradCAM++, EigenGradCAM, HiResCAM, Integrated Gradients, Guided Backprop, LIME) are computed per member; mean saliency (mu-map) and standard-deviation saliency (sigma-map) across members give explanation uncertainty. Explanations are evaluated with a new five-crop sanity check (SSIM of maps when the nodule is repositioned) and weight-randomisation checks.
Data & evaluation: LIDC-IDRI, 897 scans to 751 nodules after filtering (388 benign, 363 malignant; median malignancy 3 excluded), 80/20 stratified split; accuracy, AUC, ECE, SSIM with statistical tests across crops/randomisation levels.
Key results: Ensemble AUC 0.93 [0.88, 0.97], accuracy 85.4%, ECE 0.07 (ResNet50 88.1%, DenseNet 88.1%, ViT 81.5%, so ensemble is below its best members). GradCAM, GradCAM++, LIME pass five-crop; all but EigenGradCAM and LIME pass weight randomisation. Explanation uncertainty is uncorrelated with prediction entropy (|r| <= 0.19).
Strengths: - Fills a real gap: explanation uncertainty for nodule CT, with a systematic multi-method comparison. - Five-crop check is a simple, quantitative consistency test, and the authors note SSIM can mislead. - Candid qualitative examples of confident-but-wrong explanations.
Limitations / open questions: - Only 751 nodules, 3-member ensemble, test set ~150; ensemble underperforms single members and no baseline/ECE-matched comparison. Labels are radiologist-median scores, not pathology. - No evidence that sigma-maps help a radiologist or flag wrong explanations; the finding that they are uncorrelated with entropy is not turned into any utility test (human study, error detection AUROC). - The five-crop check passing by GradCAM may reflect blobby maps inflating SSIM; the 90th-percentile cut-off is arbitrary and the uncertain subset ROC (AUC 0.48) is not discussed as a deferral benefit.
065 · Complementary Reliability Axes for Aortic CTA Segmentation: An Empirical Audit
Authors (first/last): Thomas Olive (single author) · Affiliation: Independent researcher, Aix-en-Provence, France
Task / clinical problem: Flag likely-wrong case-level predictions of a 23-class aorta/iliac segmentation model on contrast CTA under multi-centre, contrast-phase and pathology shift.
Category tags: Segmentation uncertainty & failure detection; OOD & anomaly detection. Modality: CT angiography; aorta and iliac segmentation (nnU-Net).
Method: Audit of three post-hoc case-level signals on one nnU-Net trained on 50 AortaSeg24 cases: Mahalanobis distance on PCA-reduced encoder bottleneck features (feature-space OOD), mean pairwise Dice among T=20 MC-Dropout argmax segmentations (prediction disagreement), and centerline degeneracy (TEASAR geodesic path length < 100 mm or >= 20 components, a topology collapse detector). MSP and kNN feature distance are baselines. Signals are fused by OR, AND and standardised sum with thresholds set at the extreme in-distribution value and compared with the best single signal; no conformal guarantees are used (n_cal = 10).
Data & evaluation: 962 cases: AortaSeg24 ID test (40), AVT (56), AMOS (300), TotalSegmentator (566, agreement only). OOD-AUROC, within-cohort Unc-AUROC against Dice < 0.5/0.7, Spearman rho vs Dice, bootstrap CIs.
Key results: Mean Dice 0.752 ID, 0.727 AVT, 0.629 AMOS. Mahalanobis OOD-AUROC 0.85 on AVT but rank-correlation with Dice null and within-AMOS Unc-AUROC 0.55. Pairwise Dice: rho 0.74 ID, 0.88 AMOS, Unc-AUROC 0.94 (AMOS), AVT 0.99; near-orthogonal to Mahalanobis (rho -0.04). Centerline: Unc-AUROC 0.98 on AMOS and AVT, flag rate 0% ID / 7.1% AVT / 24% AMOS. No fusion beats the best single signal; OR-rule sends 55% (AVT) and 91% (AMOS) to review. Per-voxel variance of the same samples: AUROC ~0.50.
Strengths: - Clear separation of OOD detection from failure ranking; shows high OOD-AUROC on cross-modality cohorts is dataset identity. - Honest negative result on fusion and review-workload analysis rather than AUROC alone. - Cheap, mask-free signals; careful coverage-confound check for short scans.
Limitations / open questions: - One checkpoint trained on 50 single-centre dissection cases; shift confounds centre, phase, coverage and pathology; AVT results rest on six catastrophic cases. - Pairwise Dice costs ~10 min/case so is audit-only; “why axes separate” is speculation, and no explanation for variance-aggregator failure. - No calibrated decision rule, no clinical utility or correction-time measurement; fusion thresholds calibrated on only 40 ID cases.
069 · Contrastive uncertainty learning for robust multi-structure segmentation in lower-pelvic MR
Authors (first/last): Anonymised (double-blind submission) · Affiliation: Anonymised
Task / clinical problem: Multi-structure segmentation of lower-pelvic/prostate T2W MRI where boundary-ambiguous regions yield large surface errors not captured by Dice.
Category tags: Segmentation uncertainty & failure detection; Ensembles & Bayesian methods. Modality: MRI (T2W 3D pelvis); 8 structures (prostate zones, bladder, bone, rectum, seminal vesicle, NVB, obturator internus).
Method: Contrastive Uncertainty Learning (CUL) uses MC Dropout (M=5, decoder) predictive entropy, normalised per sample, as a training signal rather than a post-hoc filter. Voxels with low uncertainty (< 0.5) and correct prediction become anchors with same-class positives; high-uncertainty or misclassified voxels form the negative pool in an InfoNCE loss on decoder embeddings, added to DiceCE with learnable weight. Backbone is an MAE-pretrained 3D ViT with UperNet head.
Data & evaluation: 589 T2W volumes, split 412/60/117; Dice, HD95, surface distance (SD), paired Wilcoxon, case-wise improved/degraded counts, hard/easy split at median baseline HD95; ablations: class-based contrastive (no uncertainty) and Kervadec boundary loss.
Key results: Dice 0.8338 vs 0.8335 baseline (n.s.); SD 1.61 to 1.42 mm (p < 0.0001); HD95 5.93 to 5.41 mm (n.s., p=0.816; SD of HD95 8.14 to 4.88). Significant SD improvement in 6/8 structures (class-based 5/8, boundary loss 4/8). 18.8% of cases significantly improved vs 0.9% degraded (22x); hard cases mean HD95 -1.11 mm, easy ~0.
Strengths: - Novel use of uncertainty as representation-learning signal in fully supervised segmentation. - Goes beyond mean Dice with surface metrics, per-case asymmetry and hard-case stratification. - Component ablations with paired tests.
Limitations / open questions: - Gains are small (0.2 mm mean SD), HD95 and Dice not significant, and the variance-reduction claim failed its formal test; Wilcoxon p-values across 8 structures are not multiplicity-corrected. The “22x” ratio depends on arbitrary +/-0.1 mm thresholds. - Single dataset, single seed/split, no comparison to other uncertainty-aware or boundary-aware methods; the ablations differ from CUL by under 0.05 mm SD, so uncertainty guidance’s contribution is weak (the class-based variant matches CUL on HD95/SD means). - Title/abstract frame uncertainty for safety, yet no uncertainty quality (calibration, error detection) of the resulting model is evaluated, and clinical effect of 0.2 mm is asserted not shown.
070 · Beyond Mean Uncertainty: Case-wise AUSE for Detecting Failures in 3D Pelvic Tilt Estimation from a Single AP Radiograph
Authors (first/last): Daisuke Watanabe / Yoshito Otake · Affiliation: Nara Institute of Science and Technology; University of Osaka; Ehime University, Japan
Task / clinical problem: Flag unreliable 3D pelvic tilt estimates (sagittal, coronal, axial) from a single AP pelvic radiograph for hip arthroplasty/spine planning, where 2-3 degree errors matter.
Category tags: Regression & reconstruction uncertainty; Segmentation uncertainty & failure detection. Modality: X-ray (AP pelvis, with CT 2D-3D registration reference); depth-map and landmark based tilt regression.
Method: A geometry-aware pipeline predicts pelvic depth maps and ASIS/pubic tubercle heatmaps, lifts landmarks to 3D and computes tilt geometrically. Pixel-wise uncertainty maps (post-flip, inference dropout, gradient-based) are scored per case by area under the sparsification error (AUSE) computed over the pelvic ROI, comparing uncertainty-ranked vs oracle error-ranked pixel removal; the case-wise AUSE is used as an outlier score for tilt error. A reference-free linear surrogate predicts AUSE from top-N landmark-neighbourhood uncertainty products.
Data & evaluation: 2,290 AP radiographs from 559 patients (one institution; five postures), 4-fold patient-level CV; outliers by IQR rule (1.0/1.5/2.0; 58 sagittal outliers at 1.5, 6.70 deg). AUROC vs mean-uncertainty baselines (Unc. Mean/ASIS/PT) and four uncertainty estimators.
Key results: Geometry-aware MAE sagittal/coronal/axial 2.243/0.870/0.759 vs direct regression 2.915/1.349/1.249 deg. Case-wise AUSE-RMSE AUROC 0.861/0.896/0.916 (IQR 1.0/1.5/2.0), AbsRel 0.885/0.915/0.926, vs Unc. Mean 0.529/0.534/0.556. Across estimators AUSE 0.747-0.896 vs mean baselines 0.48-0.65. Reference-free surrogate AUROC only 0.654/0.669, barely above Unc. ASIS (0.650).
Strengths: - Elegant repurposing of a dataset-level metric into per-case failure score; shows mean uncertainty is nearly uninformative. - Consistent across four uncertainty estimators and IQR thresholds; patient-level CV. - Frank that AUSE is retrospective and surrogate is preliminary.
Limitations / open questions: - Case-wise AUSE needs ground-truth depth, so the headline AUROC is not deployable; the deployable surrogate is ~0.67 and not significantly better than a mean-uncertainty baseline. - Only 58 outliers, single institution, no patient-level resampling CIs or external validation; outliers defined statistically, not by clinical tolerance; advantage is sagittal-only. - AUSE depth-error ranking partly measures error concentration itself, so strong correlation with tilt error may be partly circular; no calibrated threshold or workflow benefit shown.
076 · Sequential Conformal Safety for Trustworthy Clinical Decision Pathways in Ophthalmology
Authors (first/last): Alejandro Sanchez Guinea / Mariya Erokhina · Affiliation: EyeTrustAI; Centre Hospitalier du Nord, Luxembourg; University of Cambridge
Task / clinical problem: Propagate image-derived uncertainty through multi-stage guideline-based care pathways (diabetic retinopathy with OCT-resolved macular edema; glaucoma) and guarantee a clinically safe pathway stays reachable.
Category tags: Conformal prediction & risk control; Selective prediction & triage. Modality: colour fundus photography and OCT (simulated workflows); DR/glaucoma management pathways.
Method: Patient management is a staged decision tree; stage-wise nonconformity scores combine image-model uncertainty with guideline penalties. Per-stage split-conformal quantile thresholds with miscoverage budgets alpha_t summing to alpha prune actions; by a union bound the oracle guideline pathway is retained with probability >= 1 - alpha under exchangeability. Budget allocation (uniform, front-/back-loaded, variance-weighted) is compared; a guideline-first default policy picks within the retained set.
Data & evaluation: DR: IDRiD, Messidor-2, EyePACS-5k; glaucoma: REFUGE, RIM-ONE; group-aware splits, 5 random splits, alpha=0.10; metrics existential safety, unsafe exposure in set, set size, empty-set rate, default unsafe rate; worst-group analysis. Workflows simulated over static data with rule-based oracle labels.
Key results: Existential safety 96.5-99.5% (IDRiD 99.5%, Messidor-2 97.8%, EyePACS 97.0%, REFUGE 97.2%, RIM-ONE 96.5%) at nominal 90%. Default unsafe rate 0.5-3.5%, but unsafe exposure inside retained sets up to 55.0% (IDRiD) and 70.4% (severity-4 subgroup). Variance-weighted allocation: 99.5% safe, 0.5% empty vs back-loaded 94.9%, 5.1%. Sets ~12-17 pathways; ~2 ms/patient.
Strengths: - Frames conformal guarantees at the workflow level, which matches clinical use, with explicit distinction between existential safety and decision risk. - Allocation ablation and subgroup analysis; transparent that set size is not clinical risk. - Lightweight, computationally trivial.
Limitations / open questions: - Pathways are simulated on static image datasets with rule-based oracle labels (guideline-defined), so the “ground truth” safe pathway is a deterministic function of dataset labels; no real downstream outcomes or clinicians. - Guarantee is 1-alpha by union bound (over-conservative: observed 97-99.5% vs 90% target) and retained sets are large (12-17 pathways) with up to 55-70% unsafe exposure, so the practical value rests on the heuristic default policy that has no formal guarantee; calibration sizes and nonconformity details are not given. - Exchangeability across stages/patients, no shift evaluation (within-dataset only), no baselines (e.g. single-stage CP, RCPS, selective abstention).
077 · Uncertainty-Aware Bone Age Assessment: Analysis of Conformal and Bayesian Methods
Authors (first/last): Nadide Bilge Dogan / Behcet Ugur Toreyin (co-authors Isiklan, Soydal, Kumbasar, Oksuz, Ekenel) · Affiliation: Istanbul Technical University, Turkey
Task / clinical problem: Pediatric bone age regression from hand radiographs with calibrated prediction intervals for clinical and forensic use.
Category tags: Regression & reconstruction uncertainty; Conformal prediction & risk control. Modality: X-ray (hand radiographs, RSNA bone age); regression.
Method: Multi-input (radiograph + sex embedding) regressors on EfficientNet-B3, ConvNeXtV2-Tiny and ViT-B/16. Six interval methods are benchmarked at 90/95/99% nominal coverage: vanilla split CP (constant width), kNN-CP and RF-CP (residuals normalised by local difficulty from embeddings), CQR (pinball loss with crossing penalty, conformalised), MC Dropout (T=60, Gaussian intervals) and Bayes-by-Backprop head (T=50). Intervals are the uncertainty output; widths and coverage replace a per-case decision.
Data & evaluation: RSNA 2017: train/val/calibration 6,305/3,153/3,153 (stratified), official validation 1,425 images as test; 10 seeds (each varies split and init). Metrics MAE, PICP, PINAW, CWC (eta=50).
Key results: MAE: EffNet-B3 7.52 deterministic; CQR 8.06-10.71; BNN 10.27 (ConvNeXt BNN 20.84). MCD under-covers by 7-11 points (e.g. 79.4% at 90%, CWC up to 69.8). BNN covers (95.7-97.5% at 95%) but intervals 1.5-2x wider than CP. Conformal methods near-nominal (e.g. EffNet 89.3-89.6% at 90%); RF-CP best CWC at 90% (0.325 EffNet); CQR width grows sharply at 99% (0.207 to 0.749 on ConvNeXt). EfficientNet-B3 gives tightest intervals.
Strengths: - Clean, matched benchmark: same splits/backbones/levels, 10 seeds, three coverage targets, code released. - Reports both coverage and efficiency with a penalised combined metric. - Backbone-agnostic comparison and clear practical ranking.
Limitations / open questions: - Coverage is marginal only; no conditional coverage by age, sex or bone-age range (e.g. under-coverage at extremes), so the “adaptive” benefit of RF/kNN-CP is not actually evaluated; interval widths in months not clinically interpreted. - Test set is the RSNA validation split from the same distribution; no external or shifted data, and exchangeability under real deployment/forensic populations is untested. - MCD with a single dropout and BNN head only (no deep ensembles or heteroscedastic regression baseline); CQR is trained per level and degrades accuracy, an unfair confound; conformal methods’ differences are within seed SDs.
079 · Label-Free Threshold Selection for Out-of-Distribution Detection in Liver CT Segmentation
Authors (first/last): Marshall Nielsen / McKell Woodland (co-senior Kristy K. Brock) · Affiliation: Dept. of Imaging Physics and Interventional Radiology, UT MD Anderson Cancer Center; Brigham Young University
Task / clinical problem: Turn an OOD/segmentation-quality score for a clinically deployed liver CT segmenter into review thresholds without expert-labelled failures.
Category tags: OOD & anomaly detection; Segmentation uncertainty & failure detection. Modality: CT (liver, radiotherapy contouring); failure triage for nnU-Net segmentations.
Method: The score is Pairwise Surface DSC disagreement (1 minus mean pairwise Surface DSC at 2 mm across the five cross-validation nnU-Net models). A log-t distribution fitted to scores of 400 unlabelled internal validation scans models the in-distribution; a new case gets a significance score (upper-tail probability) mapped to Low (>0.25), Medium (0.05-0.25) or High (<0.05) review risk with a priori cut-offs. Pairwise DSC needs an ordered-quantile (ORQ) normal transform instead. Compared against Youden-optimised thresholds that use labels.
Data & evaluation: Validation 400 scans (13% failure, single reader); test 500 scans (400 internal, 100 external from 70+ sites; 3.6% failure, 3-reader majority; 18 failures). Sensitivity, specificity, PPV, NPV; simulation of validation failure rate 5-40%; bootstrap of cut-offs (R=5000).
Key results: Surface DSC: Medium+High risk sensitivity 1.00, specificity 0.79, PPV 0.15, NPV 1.00; High risk sensitivity 0.78, specificity 0.96, PPV 0.45. Pairwise DSC: 0.89/0.78 and 0.61/0.98 (PPV 0.55). Youden: 0.89/0.89 (Surface DSC). Failures in Low risk: 0/383 (Surface DSC). Method degrades once contamination exceeds ~20% failures; 95% CI of Medium cut-off 0.9921-0.9938.
Strengths: - Addresses a practical annotation bottleneck with a transparent, statistically interpretable two-tier triage. - Real deployed model, multi-centre external test, cut-offs fixed a priori (not tuned on test). - Sensitivity analysis to contamination and validation size.
Limitations / open questions: - Only 18 failures in the test set (perfect sensitivity CI is wide); 79% specificity with PPV 0.15 means many false alarms; no formal coverage/risk guarantee, and thresholds (0.25, 0.05) are conventions, not justified for a target miss rate. - Assumes ID scores dominate the reference set and a good parametric fit (log-t with 3.45 df; ORQ for DSC); label shift (13% vs 3.6%) and reader differences confound comparison with Youden. - One model/organ/institution and one OOD score; no comparison with other label-free calibration (e.g. conformal/quantile of ID scores) or other detectors.